Vibration Analysis of Gears with Fatigue Crack in Tooth Root

Article Preview

Abstract:

A crack in the tooth root, which often leads to failure in gear unit operation, is the most undesirable damage caused to gear units. This article deals with fault analyses of gear units with real damages. Numerical simulations of real operating conditions have been used in relation to the formation of those damages. A laboratory test plant has been used and a possible damage can be identified by monitoring vibrations. The influences of defects of a single-stage gear unit upon the vibrations they produce are presented. Signal analysis has been performed also in concern to a non-stationary signal, using the Time Frequency Analysis tools. Typical spectrograms, which are the result of reactions to damages, are a very reliable indication of the presence of damages.

You might also be interested in these eBooks

Info:

Periodical:

Key Engineering Materials (Volumes 324-325)

Pages:

835-838

Citation:

Online since:

November 2006

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2006 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Glodez, S., Sraml, M., Kramberger, J.: A computational model for determination of service life of gears, International Journal of Fatigue, vol. 24, pp.1013-1020, (2002).

DOI: 10.1016/s0142-1123(02)00024-5

Google Scholar

[2] Belsak, A.: Razvoj sistema za odkrivanje napak na zobniškem gonilu, Master's thesis, Faculty of Mechanical Engineering, Maribor, (2004).

Google Scholar

[3] McConnel, K.G. Vibration Testing, John Wiley & Sons Inc, New York, (1995).

Google Scholar

[4] Chen, V. C., Ling, H.: Time-Frequncy Transform, Artech House Publisher, USA, (2002).

Google Scholar

[5] Gade, S., Hansen K: G.: Non-stationary Signal Analysis using Wavelet Transform, Short-time Fourier Transform and Wigner-Ville Distribution, Tehn. Rev. Bruel & Kjear, Denmark. (1996).

Google Scholar