A Study on Experimental Evaluation for Fracture Behavior of Carbon Steel Pipes for High Pressure Service with Local Wall Thinning

Article Preview

Abstract:

The locally wall thinned phenomenon of pipes is simulated as metal loss due to erosion/corrosion. Therefore, fracture behaviors of pipes with local wall thinning are very important for the integrity of nuclear power plant. In this study, monotonic bending tests without internal pressure are conducted on 1.91-inch diameter Schedule 80 STS370 full-scale carbon steel pipe specimens. We investigated fracture strengths and failure modes of locally wall thinned pipes that welded and unwelded by four point bending test. From test results, we could be divided three types of failure modes.

You might also be interested in these eBooks

Info:

Periodical:

Key Engineering Materials (Volumes 345-346)

Pages:

1349-1352

Citation:

Online since:

August 2007

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2007 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] U.K. Mudali, R.K. Dayal and J.B. Gnanamoorthy: J. Nucl. Mat. Vol. 207 (1993), p.303.

Google Scholar

[2] D.M. Goebel et al: J. Nucl. Mat. Vol. 145-147 (1987), p.61.

Google Scholar

[3] A.F. Deardorff and S.H. Bush: ASME. PVP. Vol. 186 (1990), p.71.

Google Scholar

[4] ASME Boiler and Pressure Vessel Code Section X I (1998).

Google Scholar

[5] K. Miyazaki et al: Nucl. Eng. Des. Vol. 191 (1999), p.195.

Google Scholar

[6] J.F. Mathonet et al: ASME. PVP. Vol. 303 (1995), p.393.

Google Scholar

[7] S.H. Ahn et al: Nucl. Eng. Des. Vol. 211 (2002), p.91.

Google Scholar