16 to 21 Year Clinical Results of Total Hip Arthroplasty with HA Granules at Cement-Bone Interface (Interface Bioactive Bone Cement)

Article Preview

Abstract:

To augment cement-bone bonding, hydroxyapatite (HA) granules were interposed at cement-bone interface (IBBC technique). HA granules were smeared on the bone surface just before cementing components. Porous HA granules of 300 to 500μm in diameter and 100 to 300μm in diameter were used from 1986 to 1988(first generation) and 1989 to 1991(second generation), respectively. 222 hips of 151 patients in the first generation and 252 hips of 170 patients in second generation could be followed. After 16 to 21 year follow up, radiolucent line (space), less than 1mm, was observed in 4 hips(1.8%) in the first generation and in 15 hips(6.2%) in the second generation(p<0.01). osteolysis was observed in 1 hip(0.5%) and 6 hips (1.6%), respectively. Loosening (separation) was observed only 2 cups (0.8%) in the second generation.

You might also be interested in these eBooks

Info:

Periodical:

Key Engineering Materials (Volumes 361-363)

Pages:

1299-1302

Citation:

Online since:

November 2007

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2008 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Oh I, Carlson CE, Tomford WW, Harris WH: Improved fixation of the femoral component after total hip replacement using a methacrylate intramedullary plug. J Bone Joint Surg[Am]1978; 60: 608-613.

DOI: 10.2106/00004623-197860050-00004

Google Scholar

[2] Oonishi H, Kushitani S, Aono M, et al: interface bioactive bone cement by using PMMA and hydroxyapatite granules. In: Oonishi h, Aoki H, Sawai K, ed. Bioceramics Vol. 1. Tokyo, St. Louis: Ishiyaku-Euro America, Inc., 1989: 102-107.

DOI: 10.1016/0021-9290(90)90123-k

Google Scholar

[3] Oonishi H, Kadoya Y, iwaki H, Kin N: Total hip arthroplasty with a modified cementing technique using hydroxyapatite granules. J Arthroplasty 2001; 16: 784-789.

DOI: 10.1054/arth.2001.23724

Google Scholar

[4] Oonishi H, Kadoya Y, Iwaki H, Kin N: Hydroxyapatite granules interposed at bone-cement interface in total hip replacements: histological study of retrieved specimens. J Biomed Mater Res 2000; 53: 174-180.

DOI: 10.1002/(sici)1097-4636(2000)53:2<174::aid-jbm7>3.0.co;2-o

Google Scholar

[5] Zyman Z, Weng J, liu X, et al: Amorphous phase and morphological structure of hydroxyapatite plasma coating. Biomaterials 1993; 14: 225-228.

DOI: 10.1016/0142-9612(93)90027-y

Google Scholar

[6] Geesink RGT: Osteoconductive coating for total joint arthroplasty. Clin Orthop 2002; 395: 53-65.

Google Scholar