Mesoscopic Study of Ductile Fracture of Aluminium Alloy LY12CZ

Article Preview

Abstract:

In the present paper, axisymmetric smooth and notched specimens of aluminium alloy LY12CZ were monotonic tension tested to study the ductile fracture behavior and evaluate the suitability for the critical void growth ratio, VGC of the material, from the micro and macro points of view. It's found that the material would change fracture morphology from tensile to shear failure in the various stress states; the ductile fracture parameter VGC is sensitive to the fracture morphology which is applicable for the case of tensile failure while not suitable for the case of the shear failure, i.e. the case of smooth tensile specimens.

You might also be interested in these eBooks

Info:

Periodical:

Key Engineering Materials (Volumes 261-263)

Pages:

45-50

Citation:

Online since:

April 2004

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2004 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation: