[1]
Grossman L. Endodontic practice. 9 th ed. Philadelphia: Lea & Febiger, 1978: 275-85.
Google Scholar
[2]
Schmalz G. The use of cell cultures for toxicity screening of dental materials. Advantages and limitations in Arenholt-Bindslev D, Schmalz G. Biological testing of dental materials, NOF/CED Joint Meeting, Symposium, Kolding, Denmark, august (1993).
DOI: 10.1016/0300-5712(94)90032-9
Google Scholar
[3]
Dekker A, Panfil C, Valdor M, Pennartz G, Richter H, Mittermayer C, Kirkpatrick CJ. Quantitative methods for in vitro cytotoxicity testing of biomaterials. Cell Mater 1994; 4: 101-12.
Google Scholar
[4]
Hanks CT, Wataha JC, Sun Z. In vitro models of biocompatibility: a review. Dent Mater 1996; 12: 186-93.
Google Scholar
[5]
Tronstad L, Wennberg A. In vitro assessment of the toxicity of filling materials. Int Endod J, 1980; 13: 131-138.
DOI: 10.1111/j.1365-2591.1980.tb00670.x
Google Scholar
[6]
Schmalz G. Use of cell cultures for toxicity testing of dental materials advantages and limitations. J Dent, 1994; 22: 6-11.
DOI: 10.1016/0300-5712(94)90032-9
Google Scholar
[7]
Yamagata N, Oshima H. Cytotoxic effects of restorative materials on early passage cultured cells derived from human gingiva. Shika Zairyo Kikai; 9(4): 541-554 Jul (1990).
Google Scholar
[8]
Mjor I. A.: A comparison of in vivo and in vitro methods for toxicity testing of dental materials. Int Endodont J 13, 139-142, (1980).
DOI: 10.1111/j.1365-2591.1980.tb00671.x
Google Scholar
[9]
Jaber L, Mascres C, Donohue WB. Reaction of the dental-pulp to hydroxyapatite. Oral Surg Oral Med Oral Pathol, 1992; 73: 92-98.
DOI: 10.1016/0030-4220(92)90162-j
Google Scholar
[10]
Alliot-Licht B, Jean A, Gregoire M. Comparative effect of calcium hydroxide and hydroxyapatite on the cellular activity of human pulp fibroblasts in vitro. Archs Oral Biol, 1994; 39: 481-489.
DOI: 10.1016/0003-9969(94)90144-9
Google Scholar
[11]
Yoshimine Y, Akamine A, Mukai M, Maeda K, Matsukara M, Kimura Y, Makishima T. Biocompatibility of tetracalcium phosphate cement when used as a bone substitute. Biomaterials, 1993; 14: 403-6.
DOI: 10.1016/0142-9612(93)90141-n
Google Scholar
[12]
Jean AH, Pouezat JA, Daculsi G. Pulpal responses to calcium phosphate materials. In vivo study of calcium phosphate materials in endodontics. Cells and Materials, 1993; 3: 193-200.
Google Scholar
[13]
Roberts SC Jr, Brilliant JD. Tricalcium phosphate as an adjunct to apical closure in pulpless permanent teeth. J Endodont 1975; 1: 263-9.
DOI: 10.1016/s0099-2399(75)80038-0
Google Scholar
[14]
Pissiotis E, Spångberg LSW. Biological evaluation of collagen gels containing calcium hydroxide and hydroxyapatite. J Endodont, 1990; 16: 468-473.
DOI: 10.1016/s0099-2399(07)80175-0
Google Scholar
[15]
White JM, Goodis H. In vitro evaluation of a hydroxyapatite root canal system filling material. J Endodont 1991; 17: 561-565.
DOI: 10.1016/s0099-2399(06)81722-x
Google Scholar
[16]
ISO/DIS 10993-5: In Biological evaluation of medical devices: Tests for cytotoxicity: in vitro methods. (1992).
Google Scholar
[17]
ISO/TR 7405: Biological evaluation of dental materials. (1984).
Google Scholar
[18]
van Wyk CW; Olivier A; Maritz JS: Cultured pulp fibroblasts: are they suitable for in vitro cytotoxicity testing? J Oral Pathol Med, 2001 Mar; 30 (3), 168-77.
DOI: 10.1034/j.1600-0714.2001.300307.x
Google Scholar
[19]
Schmalz G. Die Gewebeverträglichkeit zahnärztlicher Materialen Möglichkeiten einer standardisierten Prüfung in der Zellkultur. Georg Thieme Verlag, Stuttgart, New York, (1981).
Google Scholar
[20]
Denissen HW, Degroot K, Makkes PC, VanDenhoof A, Klooper PJ. Tissue response to dense apatite implants in rats. J Biomed Mater Res 1980; 14: 713-21.
DOI: 10.1002/jbm.820140603
Google Scholar
[21]
Jean A, Pouzeat J, Laboux O, Marion D, Daculsi G. Biocompatibility of various calcium phosphate materials to dental pulp. Biomaterial-Tissue Interfaces, PJ Doherty et al. (Eds. ), Advances in biomaterials, page 25-30. 1992 Elsevier Science Publishers B. V.
Google Scholar
[22]
Kooten TG, Klein CL, Kohler H, Kirkpatrick CJ, Williams DF, Eloy F. From cytotoxicity to biocompatibility testing in vitro: cell adhesion molecule expression defines a new set of parameters. J Mater Sci: Mater Med 1997; 8: 835-41.
Google Scholar
[23]
Gomes ME, Reis RL, Cunha AM, Blitterswijk CA, de Bruijn JD. Cytocompatibility and response of osteoblastic-like cells to starch-based polymers: effect of several additives and processing conditions. Biomaterials 2001; 22: 1911-(1917).
DOI: 10.1016/s0142-9612(00)00377-x
Google Scholar