Procedures for Long Term Testing of Reinforced Concrete Tension Specimens

Article Preview

Abstract:

Long term tension stiffening effects in beams and slabs were investigated by a comprehensive series of laboratory tests on tension specimens together with a small number of slabs. Some tension specimens contained strain gauged rebars to obtain very detailed data concerning reinforcement strain distributions. The results indicated that tension stiffening decayed much more rapidly than was previously thought and the important implications of this finding on the current design rules for deflection control are indicated.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

239-244

Citation:

Online since:

September 2004

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2004 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Scott, R.H. and Gill, P.A.T., Short Term Distributions of Strain and Bond Stress along Tension Reinforcement, The Structural Engineer, Vol. 65B, No. 2. June 1987, pp.39-43, 48.

Google Scholar

[2] BS8110: Structural Use of Concrete Part 1: 1997: Code of Practice for Design and Construction and Part 2: 1985: Code of Practice for Special Circumstances, British Standards Institution, London.

Google Scholar

[3] ENV 1992-1-1 Eurocode 2: Design of Concrete Structures. Part 1-1: General Rules and Rules for Buildings, British Standards Institution, London.

Google Scholar