Design, Fabrication and Study of Micro-Electrospray Chips

Article Preview

Abstract:

This paper described design, fabrication and study of micro electrospray chips. The micro electrospray chips are fabricated by using micro-electro-mechanical system (MEMS) technology. The micro electrospray techniques can be used in many applications, including high viscous fluid dispenses for 3D rapid prototyping and biological sample analysis in mass spectrometer. In this study, micro electrospray chips with different wedge angels are investigated by using microscopic visualization techniques. Four spray modes are identified at various operation voltages and currents. It is found that the voltage for stable cone-jet mode decrease as wedge angle becomes smaller. On the other hand, it is also found that stable cone-jet mode represent a constant current range in current (I)-voltage(Ф) curve. It allows us to easily identify if the micro electrospray chips operate at cone-jet mode.

You might also be interested in these eBooks

Info:

Periodical:

Materials Science Forum (Volumes 505-507)

Pages:

1249-1254

Citation:

Online since:

January 2006

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2006 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Zeleny, Industry Application of Electrospray Technology, J. Phys. Rev., 10, 1, (1917).

Google Scholar

[2] Dole, M.; Mack, L. L.; Hines, R. L. Molecular Beams of Macroions, J. Chem. Phys., 49, 2240, (1968).

Google Scholar

[3] Yamashita, M., Fenn, J. B., Electrospray Ion Source: Another Variation on The Free-Jet Theme, J. Phys. Chem., 88, 4451, (1984).

DOI: 10.1021/j150664a002

Google Scholar

[4] AlekSendriv, M. L.; Gall, L. N., Shkurov, V. A., Pavlenko, V. A., Krasnov, N. V., Nikolaev, V. I. , Mechanism of ion formation during the electrohydrodynamic sputtering of a liquid into a vacuum, , J. Anal. USSR., 39, 1268, (1984).

Google Scholar

[5] Matthias S. Wilm, Matthias Mann, Electrospray and Taylor-Cone theory, Dole's beam of macromolecules at last ?, International Journal of Mass Spectrometry and Ion Processes, 136, 167-180, (1994).

DOI: 10.1016/0168-1176(94)04024-9

Google Scholar

[6] Xue, Q., Foret, F., Dunayevskiy, Y. M., Zavracky, P. M., McGruer, N.E., Karger, B. L., Multichannel Microchip Electrospray Mass Spectrometry, Anal. Chem., 69, 426-430, (1997).

DOI: 10.1021/ac9607119

Google Scholar

[7] Ramsey, R. S., Ramsey, J, M. Generating Electrospray form Microchip Devices Using Electroosmotic Pumping, Anal. Chem., 69, 1174, (1997).

DOI: 10.1021/ac9610671

Google Scholar

[8] Amish Desai, Yu-Chong Tai, Michael T. Davis, Terry D. Lee, A MEMS electrospray nozzle for mass spectroscopy. ", Transducer, 97.

DOI: 10.1109/sensor.1997.635254

Google Scholar

[9] Xuan-Qi Wang, Amish Desai, Yu-Chong Tai, Lawrence Licklider, Terry D. Lee, Polymer-based electrospray chips for mass spectrometry. ", MEMS, 99.

DOI: 10.1109/memsys.1999.746883

Google Scholar

[10] Patrick Griss, Jessica Melin, Johan Sjodahl, Johan Roeraade, Development of micromachined hollow tips for protein analysis based on nanoelectrospray ionization mass spectrometry, J. Micromech. Microeng., 12, 682-687, (2002).

DOI: 10.1088/0960-1317/12/5/326

Google Scholar

[11] Stephen R. Wasserman, Yu-Tai Tao, and George M. Whitesides, Structure and Reactivity of Alkylsiloxane Monolayers Formed by Reaction of Alkyltrichlorosilanes on Silicon Substrates, Langmuir, 5, 1074-1087, (1989).

DOI: 10.1021/la00088a035

Google Scholar