Electrical Sliding Wear Property of Cu-Ag-Cr Alloy
Abstract:
By means of a vacuum induction furnace, Cu-Ag-Cr alloy were produced. The wear property and mechanism of Cu-Ag-Cr alloy are studied, and its property was compared with a Cu-Ag alloy. The microstructure of the Cu-Ag-Cr alloy before wear tests was analyzed by transmission electron microscopy. Worn surfaces of the Cu-Ag-Cr alloy were analyzed by scanning electron microscope (SEM) and energy dispersive X-ray spectrum (EDS). Wear tests were conducted under laboratory with a special sliding wear apparatus that simulated the tribological conditions of sliding current collectors on contact wires, and alloy wire was slid against a copper-based powder metallurgy strip under unlubricated conditions. The results show that the wear rate of Cu-Ag-Cr alloy increase with the increase in the sliding speed and the sliding distance. Adhesive wear, abrasive wear and electrical erosion wear are the dominant mechanisms under the electrical current sliding processes. At lower sliding speed, adhesives wear and abrasive wear are the major wear damage, while electrical erosion wear and adhesive wear are the major at higher sliding speed. Under the same conditions, the wear resistance of the Cu-Ag-Cr alloy is 2~3 times of the Cu-Ag alloy.
Info:
Periodical:
Pages:
497-502
DOI:
Citation:
Online since:
December 2006
Authors:
Keywords:
Price:
Сopyright:
© 2006 Trans Tech Publications Ltd. All Rights Reserved