Paper Title:
The Novel Calibration Method for 3-DOF Measurement System
  Abstract

In this paper, a novel calibration method is developed to improve the measurement accuracy of 3-DOF measurement system. The squareness error between three sensors and misalignment error with respect to reference coordinate of machine tool are calibration parameters. To estimate these parameters, reference ball is used and moved in the measuring ranges of 3-DOF measurement system. The relation between calibration parameters, position of reference ball, measured data of sensors are defined using geometric constraint and estimated using least square method. Finally, simulation is done to check the feasibility of developed calibration method. The result of simulation revealed the validation of developed method.

  Info
Periodical
Chapter
Chapter 3: Advanced Manufacturing Technology
Edited by
Jiuba Wen, Fuxiao Chen, Ye Han and Huixuan Zhang
Pages
440-443
DOI
10.4028/www.scientific.net/AMM.120.440
Citation
K. I. Lee, J. S. Jang, H. W. Lee, S. J. Kim, S. R. Lee, S. H. Yang, "The Novel Calibration Method for 3-DOF Measurement System", Applied Mechanics and Materials, Vol. 120, pp. 440-443, 2012
Online since
October 2011
Export
Price
$32.00
Share

In order to see related information, you need to Login.

In order to see related information, you need to Login.

Authors: Gang Chen, Hua Chen, Yu Bo Guo, Dong Ye
Materials and Its Applications
Abstract:This paper presents and comparison two stereo vision sensor calibration methods: Volume template based calibration method and the calibration...
397
Authors: Y.B. Ding, Jiang Ping Mei, W.C. Zhang
I. Advanced Manufacturing Technology and Equipment
Abstract:An approach of calibration method for 3D sensing scheme based on shifted point array encoding is presented. Initially a 3D calibration...
339
Authors: Ren Hao Liu, Hua Wang
Chapter 22: Mechanical and Electronic Engineering Control
Abstract:This paper presents a novel procedure to calibrate the strap-down 3-axis MEMS accelerometers for UAV navigat-ion. Firstly, we establish an...
4572
Authors: Peng Wan, Jun Jie Guo, Pei Lin Wu
Chapter 3: Industrial Robotics and Automation
Abstract:Traditional one-dimensional, two-dimensional probe can only measure the micro displacement in one or two directions of space, therefore...
1005
Authors: Jin Tao Wang, Zi Yong Liu, Lin Tong, Li Gong Guo, Xue Song Bao, Long Zhang
Chapter 2: Light/Radiation Monitoring
Abstract:The precision measurement of horizontal tank volume is one of key problems for the international trade of liquefied petroleum products....
152