Paper Title:
Failure Modes Analysis of Electromagnetic Flowmeter Based on Grey Relational Analysis
  Abstract

Firstly this paper introduces gray relation analysis, and then it draws various reasons of electromagnetic flowmeter malfunction in combination with data provided by one company. And the paper calculates the probabilities of the various reasons adopting classical statistics, and equalizes these failure rate data to get sequence difference, and then obtains grey incidence coefficient and correlation degree. Then the paper sorts these correlation degrees to confirm the influence degree of the failure modes. Finally, the bleaching information required is obtained.

  Info
Periodical
Edited by
Dunwen Zuo, Hun Guo, Hongli Xu, Chun Su, Chunjie Liu and Weidong Jin
Pages
322-326
DOI
10.4028/www.scientific.net/AMM.33.322
Citation
Z. Zhou, L.B. Li, Y. Qin, D.Z. Ma, B. Niu, "Failure Modes Analysis of Electromagnetic Flowmeter Based on Grey Relational Analysis", Applied Mechanics and Materials, Vol. 33, pp. 322-326, 2010
Online since
October 2010
Export
Price
$32.00
Share

In order to see related information, you need to Login.

In order to see related information, you need to Login.

Authors: Zhen Zhou, L.N. Zhang, Y. Qin, D.Z. Ma, B. Niu
Abstract:Characteristics of field failure data are analyzed in this paper. The failure data and sales record of LZL-type mass flowmeter are used to...
173
Authors: Wei Bin Zhu, Jin Long Meng, Zhao Qin Yin
Chapter 7: Simulation, Software development
Abstract:The rear pressure measurement position of V-cone flowmeter is in the complex vortex structure area after fluid around the cone. The...
408
Authors: Chun Yu Yu, Kai Li Zhang, De Zhong Ma, Zhen Zhou
Chapter 20: Metrology and Measurement
Abstract:With regard to the problem that only single index has been used in assessment of reliability, a suitable comprehensive assessment method...
5321
Authors: Wen Tao Ma, Sun Bin
Chapter 16: Construction Machinery and Equipment
Abstract:Flow meter coefficient calibration system is designed and developed by the software of LabVIEW, hardware of PCI-6601 and USB-6008 from NI....
3122
Authors: Kai Xia Wei, Shu Long Gu, Long Qing He
Chapter 19: Measurement Technology and Instrument
Abstract:The weight function method that uses a known weight function has been a general tool for the signal analysis of the electromagnetic...
3395