Paper Title:
The Numerical Calculation and Analysis of Burner Zone Membrane Water-Wall Temperature Field of a 600MW Supercritical Boiler under Various Operating Conditions
  Abstract

The temperature field of a 600MW supercritical boiler water-wall in burner zone is calculated based on finite-element method. Bilinear quadrilateral is used in meshing. Flux rate of the fire-facing side is calculated in section. The work condition of working medium is determined based on inlet medium and outlet medium. And heat transfer coefficient is defined. Temperature field in different working conditions is calculated to analyse the safety of the boiler.

  Info
Periodical
Advanced Materials Research (Volumes 163-167)
Edited by
Lijuan Li
Pages
664-669
DOI
10.4028/www.scientific.net/AMR.163-167.664
Citation
C. Y. Li, W. P. Yan, "The Numerical Calculation and Analysis of Burner Zone Membrane Water-Wall Temperature Field of a 600MW Supercritical Boiler under Various Operating Conditions", Advanced Materials Research, Vols. 163-167, pp. 664-669, 2011
Online since
December 2010
Export
Price
$32.00
Share

In order to see related information, you need to Login.

In order to see related information, you need to Login.

Authors: Hui Lan Huang, Gang Li
Abstract:To overcome the shortcomings of the traditional hot-water boilers, a oil-fired hot water boilers is improved design for a group-annulus...
2921
Authors: Li Bao Yin, Jing Hui Song, Zhi Yong Wen, Zheng Dong Cui, Yue Xi Yu
Chapter 1: Development and Utilization of Solar Energy
Abstract:Utilizing multi energy sources synthetically is one of the trends of energy utilization. China has splendid solar energy resource, however,...
884
Authors: Hong Yan Zhang, Cheng Wang, Yan Jun Li, Yong Ming Feng
Chapter 6: Power System and Automation
Abstract:Based on the supercharged boiler thermodynamic calculation method and turbocharged set characteristic calculation method, an integrated model...
842
Authors: Rui Zhu, Jian Xing Ren
Chapter 15: CAD/CAM/CAE/CIM
Abstract:Boiler failure is the main power plant boiler operation fault. And boiler superheater tube is one of the important reasons for boiler...
2139
Authors: Ling Da Zeng, Zhong Guang Fu, Han Cai Zeng
Chapter 12: Thermophysics, Thermal, Heat Engineering and Dynamics, HVAC and Refrigeration
Abstract:The characteristics of flow,combustion,heat transfer and NOx emission were numerically investigated under the different load operation for a...
1675