Cooling Process after HTST Orange Juice Sterilization Optimization Based on CFD |
|
| Journal | Advanced Materials Research (Volumes 201 - 203) |
|---|---|
| Volume | Advanced Manufacturing Systems |
| Edited by | Daoguo Yang, Tianlong Gu, Huaiying Zhou, Jianmin Zeng and Zhengyi Jiang |
| Pages | 2727-2730 |
| DOI | 10.4028/www.scientific.net/AMR.201-203.2727 |
| Citation | Jin Feng Wang et al., 2011, Advanced Materials Research, 201-203, 2727 |
| Online since | February, 2011 |
| Authors | Jin Feng Wang, Jing Xie, Le Ren Tao, Yong Hong Wang, Xin Yu Yang |
| Keywords | Computation Fluid Dynamics (CFD), Cooling, High Temperature Short Time Sterilization, Juice |
| Abstract | In order to study the juice cooling process after sterilization to obtain the accurate process and reduce the energy used in the cooling, the orange juice in can high temperature short time (HTST) sterilization process was calculated. The maximum temperature of juice in can was defined as 60℃. By using FLUENT, a kind of software which combines hydrodynamics, mathematics and computer technology, we were able to put different fluids into analog computation and numerical experiment to solve problems related to hydrodynamics. Orange juice cooling numerical experiment after HTST sterilization was carried out. The optimization cooling process was obtained: 20℃(293K),14 minutes;15℃(288K),13 minutes; 10℃(283K) ,13minutes; 5℃(278K), 12minutes and 0℃(273K), 12minutes. Using Carnot efficiency in Reverse Carnot cycle, the energy consumption was: 288W, 325W, 348W, 391W, 417W in accordance. And in the result, the optimized process was : 20℃(293K),12 minutes. |
| Full Paper |
Get the full paper by clicking here
|