Paper Title:
An Cold Experimental Analysis of Draught System with Chain-Grate Stoker
  Abstract

The study of cold state testing and evaluation analysis were carried on the practical running chain-grate stoker, which has an air-supply system with air storehouse and airtrough, to study the air-distribution, air leakage, air tightness and air governing. The result shows that horizontal air distribution across the furnace and the air tightness of the components such as the air port (damper) and airtrough are good. However the air leakage is large because of the complex structure and the high demand of integrated air tightness either in the front or the back of the stoker. The cost of the stoker is high because of large quantity of machine work after casting and high demand of installation, thus the structure should be improved.

  Info
Periodical
Advanced Materials Research (Volumes 230-232)
Edited by
Ran Chen and Wenli Yao
Pages
1236-1241
DOI
10.4028/www.scientific.net/AMR.230-232.1236
Citation
Z. Y. Zhang, J. H. Lu, "An Cold Experimental Analysis of Draught System with Chain-Grate Stoker", Advanced Materials Research, Vols. 230-232, pp. 1236-1241, 2011
Online since
May 2011
Export
Price