Paper Title:
Insertion Behavior of Microneedles for Drug Delivery
  Abstract

Drug dosage delivered by drug-coated microneedle is dependent on needle insertion behavior. The insertion length and gripping force at varied insertion speeds are determined quantitatively using a precision test frame. The ratio of inserted depth to pressed depth was found to rise asymptotically to a plateau, but decreased rapidly to zero insertion when the needles are pressed less than 1000 microns deep for both silicone rubber and porcine skin. No insertion was observed when the needles are pressed less than 200 microns. The gripping force exerted onto the inserted needle by the skin decreased by 0.1N per mm of needle diameter and insertion depth. The short insertion depth and low force suggest that drug delivery using short 300 micron microneedles would be tenuous. High insertion speeds can help to improve drug delivery, but the improvement is limited to large needles since the results from this study showed that insertions become speedindependent when the needle diameter is less than 130 microns.

  Info
Periodical
Advanced Materials Research (Volumes 47-50)
Edited by
Alan K.T. Lau, J. Lu, Vijay K. Varadan, F.K. Chang, J.P. Tu and P.M. Lam
Pages
1442-1445
DOI
10.4028/www.scientific.net/AMR.47-50.1442
Citation
K.T. Shek, D. C.C. Lam, "Insertion Behavior of Microneedles for Drug Delivery", Advanced Materials Research, Vols. 47-50, pp. 1442-1445, 2008
Online since
June 2008
Export
Price
$32.00
Share

In order to see related information, you need to Login.

In order to see related information, you need to Login.

Authors: Chang Yong Lee, Won Bae Lee, Yun Mo Yeon, Keun Song, Jeong Hoon Moon, Jung Gu Kim, Seung Boo Jung
Abstract:The microstructure and mechanical properties of spot friction stir welded A 5052 alloy were investigated with insertion depth of welding...
345
Authors: Renae Mulligan, Ling Yin, Anthony Lamont, Zhong Xiao Peng, Mark R. Forwood, Swee Hin Teoh
Abstract:Bone biopsy is a common procedure in bone disease diagnoses, therapies and research. In this procedure, bone biopsy needles are inserted into...
2225
Authors: De Dong Gao, Hao Jun Zheng
Abstract:Needle deflection and soft tissue deformation are the most important factors that affect accuracy in needle insertion. Based on the...
889
Authors: Yan Cheng Wang, Bruce L. Tai, Roland K. Chen, Jason Moore, Carl S. Mcgill, Kai Xu, Patrick W. McLaughlin, Albert J. Shih
Abstract:Needle is one of the most common features in medical devices. A better understanding of needle tip geometry can lead to the creation of an...
13
Authors: Maximiliane Erhardt, Carsten Kaschube, Markus Menacher
Chapter 4: Improved Product Quality by Online Monitoring and Closed-Loop Control of Manufacturing Processes
Abstract:To provide high quality in production and assembly processes need to be controlled. This paper analyzes the effect and necessity of online...
140