Paper Title:
Thinning Technology of Patterned Silicon Wafer for Micro Pressure Sensor
  Abstract

Recently, the research of the gene using the transgenic mouse has been performed for the development of new medicines. However, 600,000 kinds of mice are produced for the elucidation of each gene function. For this reason, the intelligent microchips have been developed to obtain an individual identification and biological information. The ventricular rate of a mouse can be monitored by the micro pressure sensor mounted on the intelligent microchip. In this research, the detailed structure and functions of the micro pressure sensor were investigated by the FEM analysis, and the sensor-chips were manufactured on 6-inch silicon wafer. The wafer thickness had to be reduced owing to the size restriction of the intelligent microchip. The grinding of the 6-inch silicon wafer with 560 µm in thickness with 19200 sensor-chips was carried out by the newly developed thinning technology. After the basic characteristics of a sensor-chip were evaluated, the output profile containing small peaks corresponding to the heartbeat of a transgenic mouse was finally detected using a mounted sensor-chip.

  Info
Periodical
Key Engineering Materials (Volumes 291-292)
Edited by
Yury M. Baron, Jun'ichi Tamaki and Tsunemoto Kuriyagawa
Pages
419-424
DOI
10.4028/www.scientific.net/KEM.291-292.419
Citation
T. Nagano, M. Touge, J. Watanabe, "Thinning Technology of Patterned Silicon Wafer for Micro Pressure Sensor", Key Engineering Materials, Vols. 291-292, pp. 419-424, 2005
Online since
August 2005
Export
Price
$32.00
Share

In order to see related information, you need to Login.

In order to see related information, you need to Login.

Authors: Jin Feng Bai, Shi Yong Wu, Shao Feng Li, Wei Chen, Yan Li
Abstract:A novel tube-form asymmetrical carbon membrane based on phenol-formaldehyde resin (PFR) is proposed in this paper. The membrane is composed...
457
Authors: Christian Bolzmacher, Karin Bauer, Ulrich Schmid, Helmut Seidel, Moustapha Hafez
Abstract:The amplitudes of miniaturized electromagnetic actuators are clearly enhanced if the eigenfrequencies of the membrane are used for...
141
Authors: P. Moonsri, S. Watanesk, R. Watanesk, H. Niamsup, Q. Cheng, R.L. Deming
Abstract:Stable silk fibroin (SF) membranes were prepared by modifying SF with polyethylene glycol diglycidyl ether (PEGDE) for use as enzyme...
265
Authors: Zhen Lin, Chang Hui Wang, Yu Liu
Abstract:A simple model specific to static water feed solid polymer electrolyte (SPE) water electrolysis cell is constructed containing Butler-Volmer...
750
Authors: Cai Xia Luo, Xiao Xia Guo
Chapter 2: New Material Application in Manufacturing
Abstract:To study the stress condition at the junction of the spherical shell with opening nozzle, using the finite element analysis, a finite element...
274