Paper Title:
Surface Modification Effect of Wettability on the Performance of PDMS-Based Valveless Micropump
  Abstract

Experimental investigation and numerical simulation on the effect of surface wettability on the performance of a polydimethylsiloxane (PDMS) based diffuser micropump are presented. A valveless micro membrane pump with piezoelectric actuation has been examined. Using a replica molding technique, the valveless micropump was made of PDMS on a Pyrex glass substrate. A thin piezoelectric (PZT) disc was used as an actuator. Poly vinyl alcohol (PVA) and octadecyltrichlorosilane (OTS) coatings, which make the coated surface hydrophilic and hydrophobic, respectively, were used to modify the surface wettability inside the pump. In our experiments, the contact angle of the PDMS surface changed from 96.6 o to 29.1 o and 99.6 o by PVA and OTS coatings, respectively, and the contact angle of glass changed from 33.2 o to 17.5 o and 141.8 o. A self-priming process was numerically simulated in a diffuser element using a computational fluid dynamics program (CFD-ACE+). The results show that fewer gas bubbles were created in the hydrophilic coated pump than in the hydrophobic coated one as time progressed. This agrees well with experimental observations. Steady-state flow rates of the micropump were measured. Compared to the non-coated pump, the flow rate increased slightly with the hydrophobic coating but decreased with the hydrophilic coating. We determine that surface wettability significantly affects the performance of a PDMS-based micropump.

  Info
Periodical
Key Engineering Materials (Volumes 326-328)
Edited by
Soon-Bok Lee and Yun-Jae Kim
Pages
297-300
DOI
10.4028/www.scientific.net/KEM.326-328.297
Citation
W. Cho, Y. J. Ko, Y. M. Ahn, J. Y. Yoon, N. G. Cho, "Surface Modification Effect of Wettability on the Performance of PDMS-Based Valveless Micropump", Key Engineering Materials, Vols. 326-328, pp. 297-300, 2006
Online since
December 2006
Export
Price
$32.00
Share

In order to see related information, you need to Login.

In order to see related information, you need to Login.

Authors: Yu Tang Chen, Chin Chun Hsu, Shung Wen Kang, Lung Chi Wu
Abstract:This study describes the results on the fabrication, testing and analysis of curved micro nozzle/diffuser. First, we use different polymers,...
357
Authors: Li Tian, Wei Wang, Xiao Wei Liu, Ying Zhang, Shu Yi Ji
Abstract:A new low cost high performance PMMA micropump, developed for microfluidic system, is presented. According to the orifice flow theory, a...
198
Authors: Tsung Hsing Chan, Chiang Ho Cheng, An Shik Yang, Li Yu Tseng
Abstract:The current paper endeavors to present the design, fabrication, and test of a novel valveless piezoelectrically actuated micropump. The...
227
Authors: Ling Ling Sun, Shan Zhong Wang, Ling Na Li, Jin Lan Guo, Siti Fatimatuzzahra Binti Roseli
Abstract:Micropumps represent one of the major components in microfluidic technology. This paper describes the fabrication and performance testing of...
179
Authors: Ryuta Ikoma, Hiroki Komatsuzaki, Takayuki Komori, Keigo Kuroda, Hirofumi Saito, Yasushiro Nishioka
Chapter 5: Materials Science and Technology, Material Manufacturing Processes
Abstract:Air-actuated valveless micropumps with dual polyimide (PI) diaphragms have been fabricated and characterized. A 5-μm-thick PI membrane was...
1364