Paper Title:
Parameter Calibration of Hartmann-Shack Wavefront Sensor Based on Mode-Construction Algorithm
  Abstract

The principle of Hartmann-Shack wavefront sensor decided that the distance between micro-lens array and the CCD is the essence of reconstruction algorithm. Because of lacking way to measure the parameter and the existing of assembly error, it will obviously cause error by using the micro-lens focus instead of actual parameter. After analyzing the Zernike polynomial for describing wavrfront aberration, a new Self-reference method is given in this paper to calibrate the parameter. The method is based on the truth that the primary aberration of point light source is defocusing amount. Through this way, the requirement of sensor assembly-precision is reduced, and the detection accuracy of Hartmann-Shack sensor is also improved in the meanwhile. Satisfying results has been achieved under the normal experimental condition using the method given in this paper.

  Info
Periodical
Key Engineering Materials (Volumes 426-427)
Edited by
Dunwen Zuo, Hun Guo, Guoxing Tang, Weidong Jin, Chunjie Liu and Chun Su
Pages
638-642
DOI
10.4028/www.scientific.net/KEM.426-427.638
Citation
C. Liang, W.H. Liao, J.X. Sheng, "Parameter Calibration of Hartmann-Shack Wavefront Sensor Based on Mode-Construction Algorithm", Key Engineering Materials, Vols. 426-427, pp. 638-642, 2010
Online since
January 2010
Export
Price
$32.00
Share

In order to see related information, you need to Login.

In order to see related information, you need to Login.

Authors: Jia Bi Chen, Pei Ming Zhang, Song Lin Zhuang
Abstract:An information fusion method measuring human eye aberrations is presented here. We have built an optical setup to combine two systems, which...
379
Authors: Xiang Zhang
Chapter 3: Material Science, Chemistry and Information Technology
Abstract:Results of an experimental and theoretical analysis of the proprerties of a LD pumped laser using a plano-concave stable resonator and KTP...
505
Authors: Xiang Zhang
Structural Strength and Robustness
Abstract:Results of an experimental and theoretical analysis of the proprerties of a LD pumped laser using a stable resonator and second harmonic...
1444
Authors: Chun Liang, Jian Xin Shen, Sai Sai Niu
Chapter 2: Devices and Instruments for Detection, Monitoring and Measuring
Abstract:Ocular retinal imaging is a major diagnostic modality for retinal disease, and can play a critical role for diagnosing systemic diseases such...
213
Authors: A.C. Xu, J.B. Chen, P.M. Zhang, J.J. Wu
Chapter 3: Other
Abstract:Human eyes is an imperfect imaging system that has various aberrations such as on axis and off axis aberrations, which often affect the...
183