Papers by Author: Jeong Ki Lee

Paper TitlePage

Abstract: The elastic waves in the isotropic plate are dispersive waves with the characteristics of Lamb wave, however, S0 symmetric mode is less dispersive in the frequency region less than the first cut-off frequency. In the anisotropic plates such as CFRP plates, the propagation velocities vary with the directions as well as the dispersion of the Lamb wave, and the phase velocity direction does not accord with the group velocity direction. The phase velocity direction is equivalent the wave vector direction, while the group velocity direction is equivalent the energy flow direction. In this work, the group velocity dispersion curves were obtained by the dispersion relation of the Lamb wave in unidirectional CFRP plate with an orthotropic structure. The group velocities of the S0 symmetric mode in the frequency region less than the first cut-off frequency were corrected by applying the slowness surface. The propagation velocities of Lamb wave were decided by measuring the arrival time of the Lamb wave signals received with the two pinducers varying the propagating direction in the laminated unidirectional CFRP plates of 8, 16 and 24 plies having a volume fraction of 67%. The measured velocities are better agreement with corrected group velocity curve, except near the fiber direction at the cusp region. When the propagating direction is not accorded with the principal axis, the direction of the group velocities inclines toward the fiber direction in the unidirectional CFRP plates, suggesting that the energy propagates preferentially toward fiber direction.
2213
Abstract: The conventional eddy current testing uses a sinusoidal signal with very narrow frequency bandwidth. Whereas, the pulsed eddy current method uses a pulse signal with a broad frequency bandwidth. This allows multi-frequency eddy current testing, and the penetration depth is greater than that of the conventional eddy current testing. In this work, the pulsed eddy current instrument was developed for evaluating the metal loss. The developed instrument was consist of the pulse generator generating the square pulse of maximum 40 V, the amplifier controlled to 52dB, the A/D converter of 16bit 20MHz, and the industrial personal computer for operating with Windows program. And, the probe for the pulsed eddy current was designed as the pancake type in which the sensing coil was located in the driving coil. The peak voltage did not linearly increase with the voltage of the step pulse. For the driving coil with inductance of 670µH, the peak voltage linearly increased with the step pulse voltage to 30V. But, for the other driving coils with the inductance of 1.7mH, 2.7mH, 3.6mH, 22mH, the peak voltage linearly increased with the step pulse voltage to 20V. The output signals of the sensing coil rapidly increased when the step pulse driving voltage was off, and the latter part of the sensing coil output voltage exponentially decreased with a time. The decrement value of the output signals of sensing coil increased with the thickness of the aluminum test piece.
2028
Showing 1 to 2 of 2 Paper Titles