Papers by Author: Lih Horng Shyu

Paper TitlePage

Abstract: Interferometric signals of a homodyne Michelson interferometer appear in sinusoidal forms. In this investigation, new concepts for signal processing of Michelson interferometer are demonstrated. With the utilization of detection of position sensitive detector (PSD) and by the procedure of differential signals and the characteristic of symmetric waveform, a compact signal processing for homodyne Michelson interferometer has been developed. Its advantages include simplified procedure, fast processing and few electronic hardware. For experiment tests of the signal processing, a conventional homodyne Michelson interferometer has been constructed. Major components of the interferometer consist of laser light source, beam splitter, mirrors, PSD and piezo transducer for driving measurement mirror. To verify the performance of the signal processing, a commercial nanopositioning stage as reference standard has been utilized for comparison measurements. Through theoretical analysis and experiment tests, it can be proved that by the developed signal processing an interferometer possesses the optical resolution of 79 nm. With support of the developed signal processing, interferometers will possess the benefits of simply structure, few components and lower cost.
98
Abstract: The construction of Fabry-Perot interferometer is very simple and it has been already utilized in different measurement systems. The result of displacement measurement is obviously influenced by the tilt angles of measurement mirror, if a Fabry-Perot interferometer is utilized for displacement measurement. Hence, the measuring range of current systems is rather small (less than 1 mm). The goal of this investigation is to develop a Fabry-Perot interferometer for large travelling range (till 60 mm) by aid of compensation of tilt angles with an angular sensor, piezo translators, control mechanism and self-designed software. To verify the measuring characteristic of the self-developed Fabry-Perot interferometer, some comparison measurements have been performed. A commercial laser interferometer serves as reference standard and the differences between Fabry-Perot interferometer and the commercial Laser interferometer are measured. Through experimental tests, the differences are less than 0.3 m in the full measurement range. The results show that the Fabry-Perot interferometer can meet the measuring requirement with high accuracy of sub-micrometer order and large measurement range.
95
Abstract: A new optical encoder system is presented for displacement measurement by the curve fitting method. In this paper, another pondering model is based on the previous development. That is the new measurement method using a homemade periodical gray level code, which can be used to replace the traditional doublet grating. A high precision is achieved by a fitting method with one single-frequency harmonic function. The experiment result shows that the concept is feasible.
349
Showing 1 to 3 of 3 Paper Titles