Authors: Sang Sik Lee, Choong Ho Lee, Young Tae Cho
Abstract: Si-Mn spring steel (JIS SUP 9) is primarily employed in the construction of coil springs,
particularly those used in soil cultivators deployed in harsh environments. This is due to its specific
properties, which allow it to resist permanent deformation, and also provide rapid and effective
vibration relief. Si-Mn spring steel (JIS SUP 9) for use in such projects is normally subjected to oil
quenching and heat treatment, in order to strengthen its resistance to both impact and fatigue.
Unfortunately, oil quenching is associated with environmental issues, most notably pollution and the
contamination of wastewater with oil. Therefore, the objective of this study was to describe an
alternative aqua quenching for use with this heat treatment. However, aqua quenching has
traditionally conferred a lower tensile laod than does oil quenching. This problem of lesser tensile
load was solved by properly controlling the density and temperature of the aqua quenching liquid, as
well as careful mixing. As a result, it has proven possible to achieve results with aqua similar to those
conferred by oil quenching, with regard to chemical components, tensile load, and surface hardness.
The tensile load results achieved by oil quenching were 13,145 Pa and 17,177 Pa, and the tensile
loads achieved with aqua quenching were 15,392 Pa, 16,804 Pa, 17,923 Pa, and 18,668 Pa. Therefore,
the results of our experiments demonstrated the appropriacy and efficacy of this aqua quenching
technique as a component of heat treatment for Si-Mn spring steel (JIS SUP 9).
249
Authors: Sang Sik Lee, Ki Young Shin, Joung H. Mun
Abstract: The objective of this study was to develop a portable, wireless surface EMG of a
noninvasive type. The limitations of the existing system include its large size and the necessity of a
wire. Therefore, this study focused on the development of a portable and wireless type of EMG. The
developed EMG, which has 10 channels, is composed of an electrode for the measurement of the
EMG signal, a preamplifier for initial processing, a second amplifier, an A/D converter, and a
Bluetooth module for wireless communication. The communication of the developed EMG used a
UART (Universal Asynchronous serial Receiver and Transmitter) and Bluetooth protocols. The rate
of serial communication was set to 723kbps. This system is able to obtain 2,000 Hz in each channel.
The data transfer success rate of the developed EMG is 100%.
1107
Authors: Yong K. Moon, Yu H. Song, Jae H. Kim, Sang Sik Lee, Joung H. Mun
Abstract: The objective of this study was to develop an Ethernet-based telemedical blood pressure
monitor. Although telemedical applications utilizing a variety of media are currently available,
present systems do not provide remote signals with regard to integrated vital information, including
blood pressure and pulse rate. In addition, the existing systems are largely embedded-structure,
single-access, single-process models. Thus, we developed an Ethernet-based blood pressure monitor
which includes a client/server structure, and is a real-time multi-access and multi-process system. The
client for the developed system uses the Microsoft Comm Control in Microsoft Visual Basic and
ODBC to connect Microsoft Chart Control with DB for a user interface. The server is programmed
with the J2SE development platform, in a multi-thread structure. The system is capable of receiving
data simultaneously. A TCP/IP socket was used for the Ethernet connection. The JDBC was applied
to connect with the database for the saving, searching, and sampling of the data. The data transfer
failure rate of the developed system was determined to be less than 0.05%.
1103
Authors: Tae Yong Sim, Seung Eel Oh, Sang Sik Lee, Joung H. Mun
Abstract: In golf, it is crucial that unintended shots, such as slices, be minimized. However, it has
proven rather difficult to improve golf performance via investigations of the causes of slicing, as this
particular phenomenon is induced by a cooperative effect by each segment of the body, rather than by
a single postural anomaly. Thus, the objective of this study was to isolate and characterize the factors
causing slicing, and to present possibilities for the improvement of golf performance via the
minimization of the number of slices executed, using a three dimensional motion capture system,
combined with multiple regression analysis, artificial neural network, and fuzzy logic techniques.
This study obtained some interesting results, such as the following: (1) We isolated 9 slice-inducing
factors, using a stepwise method. (2) Our artificial neural network (ANN) accurately separated 'slice'
from 'normal' shots (classification rate: 100%). (3)We could present the possibility of reducing the
number of slice using the fuzzy logic. We expect that our data might be eventually used to improve
golf performance.
1094
Authors: Yong Hoon Rim, Ahn Ryul Choi, Sang Sik Lee, Joung H. Mun
Abstract: The purpose of this study is to calculate the length and velocity change of gastrocnemius
and soleus muscle-tendon complex (MTC) for diagnosis and estimation of the rehabilitation
procedure of the patient from non-invasive 3D markers. The previous method measuring the length of
MTC has been dependant on the regression equation based on the rotation angle in the sagittal plane.
However, in view of the fact that movement analysis is based on the human body having a variety of
structure, the measurement using merely rotation angle and regression equation which not based on
each subject shank and foot length might not be accurate. In order to overcome these limitations, the
length change of MTC is calculated, employing 3D MTC model accompanied with the trajectory data
of markers attached anatomical landmarks, each subject measurements and femur condyle radius.
Basically, more accurate length change could be acquired through the 3D trajectory data of markers in
comparing with 2D data based on the rotation angle.
As our study, the difference of the gastrocnemius length change between 3D marker trajectory
based method and the method using a 2-D angle was approximately 4% (2cm) at maximum
contraction and 1% (0.5cm) at maximum relaxation. Similarly, the difference in terms of the soleus
was approximately 0.7% (0.3cm) at maximum contraction and 0.5% (0.2cm) at maximum relaxation.
1090
Authors: Yong Hoon Rim, Young Jin Kim, Sang Sik Lee, Joung H. Mun
Abstract: Equinus gait, defined as walking on one forefoot or both forefeet, has long been considered
an undesirable characteristic in patients with a variety of neuromuscular disorders. In the equinus gait,
the heel contact pattern is changed according to the severity, because an excessive ankle plantar
flexion instigates rearfoot lifting in patients. However, no biomechanical severity index exists to
evaluate the rehabilitation procedure of equinus gait. Therefore, we developed an SIEG (Severity
Index of Equinus Gait) for nondestructive evaluation of the equinus gait and to validate the index with
regard to 11 kinematic and kinetic factors of gait analysis. In this study, the 3-D heel contact pattern
was considered for the development of a severity index. In order to verify the result, we compared the
developed severity index values with ankle joint kinematic and kinetic factors in 3 test groups. As a
result, the average SIEG values ranged between 10.45 (Normal group) and 26.61 (Severe group) and
the highest correlation with regard to the 3 groups was shown in the developed severity index.
Additionally, we also presented a fuzzy model using Takagi-Sugeno-Kang(TSK) logic with regard to
the 12 factors in order to more accurately classify equinus gait.
1086
Authors: Sang Sik Lee, Ki Young Shin, Joung H. Mun
Abstract: Currently available foot pressure sensors (FPS), which usually include a capacitive sensor
and a piezoresistive sensor, tend to exhibit characteristically slow response times. Therefore, we used
PZT (lead zirconate-titanate) ceramic in this study, as it responds more quickly than the
currently-used materials. We have developed an algorithm which can be applied to the PZT
ceramic-based measurement of foot pressure. This algorithm was also verified in experiments. In this
study, we fabricated the electronic circuits and a sensor on the basis of the newly-developed
algorithm, and then verified the algorithm experimentally.
1111