Papers by Keyword: Fracture Fixation

Paper TitlePage

Abstract: This paper proposes a new iterative method to achieve an optimally fitting plate for pre-operative planning purposes. The proposed method involves integration of four commercially available software tools, Matlab, Rapidform2006, SolidWorks and ANSYS, each performing specific tasks to obtain a plate shape that fits optimally for an individual tibia and is mechanically safe. A typical challenge when crossing multiple platforms is to ensure correct data transfer. We present an example of the implementation of the proposed method to demonstrate successful data transfer between the four platforms and the feasibility of the method.
382
Abstract: Virtual methods to assess the fitting of a fracture fixation plate were proposed recently, however with limitations such as simplified fit criteria or manual data processing. This study aims to automate a fit analysis procedure using clinical-based criteria, and then to analyse the results further for borderline fit cases. Three dimensional (3D) models of 45 bones and of a precontoured distal tibial plate were utilized to assess the fitting of the plate automatically. A Matlab program was developed to automatically measure the shortest distance between the bone and the plate at three regions of interest and a plate-bone angle. The measured values including the fit assessment results were recorded in a spreadsheet as part of the batch-process routine. An automated fit analysis procedure will enable the processing of larger bone datasets in a significantly shorter time, which will provide more representative data of the target population for plate shape design and validation. As a result, better fitting plates can be manufactured and made available to surgeons, thereby reducing the risk and cost associated with complications or corrective procedures. This in turn, is expected to translate into improving patients' quality of life.
685
Abstract: Intramedullary (IM) nails are routinely used to stabilize long bone fractures. They can however lead to stress shielding, pain, migration, obstruct hematopoietic tissue, become a loci for infection, and require subsequent surgical retrieval. Novel intra-osseous scaffold (IOS™) prototypes for fracture healing have been developed to function as a regenerative scaffold to enhance callous formation under mechanically stabilized conditions then resorb. Prototype fixation pins and rod systems were formed from glass-reinforced-glass. Flexion, torsion and shear tests were performed to evaluate the composite pins and rods. A modular rod design was successfully deployed and dilated while in a deformable state. When fitted and gripping the intramedullary canal then set in a rigid state. An obliquely sectioned ovine femur was used as a long bone fracture model for deployment and mechanical verification. Flexural support provided by the intramedullary scaffold was superior to multiple k-wire fixation, while the k-wire approach was more stabilizing under torsional loads. Glass reinforced glass samples were mechanically tested after soaking for up to 4 weeks in saline. Strength and modulus of the composite was reduced to approximately 25% of initial values after 2 weeks.
81
Showing 1 to 3 of 3 Paper Titles