A New Approach to Exergy Analyses of a Hybrid Desiccant Cooling System Compares to a Vapor Compression System

Abstract:

Article Preview

In the recent researches HVAC with a based desiccant dehumidifier with a low ambient impact is more efficient in comparison to the traditional systems. Hybrid desiccant cooling systems can be used to control indoor air quality in buildings. This paper presents an integrated energy, entropy and exergy analysis of a hybrid desiccant cooling system compare to a compression system based on first and second laws of thermodynamic. The main objective is the use of a method called exergy costing applied to a conventional compression system that has been chosen to provide the proper conditioned air for a building in hot and humid condition. By applying the same method for the equivalent hybrid cooling system and finding the same exergy costing parameters, two systems can be in comparison to find the more economical system. The result illustrated hybrid desiccant cooling system can be providing 19.78% energy saving and 14.5% cheaper than the compression system the same capacity and lifetime. Nomenclature:

Info:

Periodical:

Edited by:

Wu Fan

Pages:

2163-2169

Citation:

S. Khosravi et al., "A New Approach to Exergy Analyses of a Hybrid Desiccant Cooling System Compares to a Vapor Compression System", Applied Mechanics and Materials, Vols. 110-116, pp. 2163-2169, 2012

Online since:

October 2011

Export:

Price:

$38.00

[1] J. J. Jurinak, J. W. Mitchell, and W. A. Beckman, Open-cycle desiccant air conditioning as an alternative to vapor compression cooling in residential., Tran. ASME, vol. 106, pp.252-258, (1984).

DOI: https://doi.org/10.1115/1.3267593

[2] D.G. Waugaman, A. Kini, and C. F. Kettleborough, D.G. Waugaman' A. Kini' C.F. Kettleborough'" A review of desiccant cooling systems, Energy Resources vol. 115, pp.1-8, (1993).

DOI: https://doi.org/10.1115/1.2905965

[3] P. L. Dhar and S.K. Singh, Studies on solid desiccant based hybrid air conditioning systems, Applied Thermal Engineering, vol. 21, pp.119-134, (2001).

DOI: https://doi.org/10.1016/s1359-4311(00)00035-1

[4] J.R. San and J.C. Fischer, Active desiccant integration with packaged roof top HVAC equipment, Applied Thermal Engineering, vol. 25, pp.3138-3148, (2005).

DOI: https://doi.org/10.1016/j.applthermaleng.2005.04.007

[5] ANSI/ASHRAE, Ventilation for acceptable indoor air quality., vol. 62 Atlanta: American Society of Heating and ventilation and air conditioning engineers, (2005).

[6] A. Bejan, G. Tsatsaronis, and M. Moran, Thermal design and optimization. NC: USA: John Wiley & Sons, (1996).

[7] http: /www. irimet. net/weathermap: Portal of Islamic Republic of Iran Metrological Organization, (2010).

[8] L. Harriman, 20 Years of commercial desiccant systems, Tran. Symposia June 2003, pp.43-54.

[9] Peter and G. Demakos, Improving indoor air quality with quality with liquid desiccant dehumidification, New York: In: HPAC Engineering, Tran. Symposia, September (2010).

[10] http: /www. moe. org. ir/latin: Portal of Iran Power Generation Company, (2010).

[11] Meckler, M. R. Herriman, J. Fischer, and K. McGahey, Desiccant Technology Transfer Workshop Manual, " Arlington, Virginia: American Gas Cooling center, (1995).

[12] EPRI, Survey of utility demand-side management programs, California: Electric Power Research Institute, (1993).

[13] Mei, V. C, F. C. Chen, Z. Lavan, R. K. C. Jr., and G. Meckler, An assessment of desiccant cooling and dehumidification technology, Oak Ridge National Laboratory'ORNL\Con-309, Tennessee, (1992).

DOI: https://doi.org/10.2172/10103029

[14] Desiccant wheel selection program' www. novelaire. com/ soft_ware. html, Novelaire Technologies, (2009).

Fetching data from Crossref.
This may take some time to load.