Structural Failure Analysis of Shaft of Wobbly and Attrited Testing Equipment

Abstract:

Article Preview

In order to research the fatigue strength of gasket which is with new composite material in one plane, we designed and manufactured special testing equipment. The material of shaft of testing equipment is 30CrMnSi. In the experiment, the 30CrMnSi shaft was broken into two parts by suddenly. By structural analysis, static analysis and heat treatment analysis for shaft, we get the reason of fracture for shaft finally. The problem solved make the test goes well and can help design and manufacture testing equipment in the future.

Info:

Periodical:

Edited by:

Jing Guo

Pages:

105-108

Citation:

Y. C. Liu and Y. Zuo, "Structural Failure Analysis of Shaft of Wobbly and Attrited Testing Equipment", Applied Mechanics and Materials, Vol. 224, pp. 105-108, 2012

Online since:

November 2012

Export:

Price:

$38.00

[1] Metal Fracture Analysis[M]. Beijing: National Defence Industry Press, 1979. 27-46.

[2] Fanping Deng, ANSYS 10. 0 Analysis of Finite Element. Beijing: Post and Telecom Press, 2007. 1.

[3] Yuanqing Wang, Xiaozhe Wang, Yanmin Wu. Experimental study about mechanical properties of structural steel is at low temperature[J]. Industry Building, 2001, 31(12): 63-65.

[4] Delin Shu. Mechanical Properties Of Engineering Materials[M]. Beijing: Mechanical Industry Press, 2003. 13.

[5] Aiguo Liu, Jie Li. Research about heat treatment process[J]. Mechanical Engineering and Automation, 2004, 5(4): 45-47.