Numerical Investigation of the Circle Grids Fractal Flow Conditioner for Orifice Plate Flowmeters

Abstract:

Article Preview

Flow rate measurements are among the most important operations in modern industries dealing with increasingly expensive fluids such as petroleum, natural gas and water. The accuracy of flow meters depends mainly on their position in a pipe network and their operating conditions. Pipe fittings such as valves and bends generate turbulence and swirl and distort the flow distribution in the pipe, leading to a substantial amount of measuring error. For accurate flow rate measurements, the standards ISO 5167 specify either a sufficient straight piping lengths or the inclusion of a flow conditioner between the flow distortion and the flow meter. Flow conditioners serve to reduce the developing length between pipe fittings and flow meters and to create fully developed flow condition within short distances. In the present study, numerical modeling of the flow development upstream and downstream of the orifice plate which used circle grid fractal flow conditioner has been made. Computational Flow Dynamics techniques have been used to predict the flow development downstream the flow conditioners.

Info:

Periodical:

Edited by:

Mohamed Othman

Pages:

700-704

Citation:

B. Manshoor and A. Khalid, "Numerical Investigation of the Circle Grids Fractal Flow Conditioner for Orifice Plate Flowmeters", Applied Mechanics and Materials, Vols. 229-231, pp. 700-704, 2012

Online since:

November 2012

Export:

Price:

$38.00

[1] Aichouni, M., Laws, E. M., and Ouazzane, A. K., Experimental study of the effects of upstream flow condition upon venturi flow meter performance,., In Flow Modelling and Turbulence Measurements VI, pp.209-216, (1996).

[2] Aichouni, M., Mous, M., Benchicou, S., Mouaici, M., Belghit, M., and Mechmeche, M., How flowmeter condition affects measurements accuracy, Proceeding of the 7th International Symposium on Flow Modelling and Turbulence Measurements, Tainan, Taiwan, October 5 - 7. (1994).

[3] Yeh, T. T., and Mattingly, G. E., Flow meter installation effects due to a generic header, NIST Technical note 1419. (1996).

[4] ISO 5167, Measurement of fluid flow by means of orifice plates, nozzles and Venturi tubes inserted in circular cross section conduits running full., (1991).

DOI: https://doi.org/10.3403/01626280u

[5] Manshoor B., Nicolleau, F. C. G. A., and Beck, S. B. M., The fractal flow conditioner for orifice plate flow meters, Flow Measurement and Instrumentation, 2011. 22(3): pp.208-214. (2011).

DOI: https://doi.org/10.1016/j.flowmeasinst.2011.02.003

[6] Launder, B. E., and Spalding, D. B., The numerical computation of turbulent flows,. Computer methods in Applied Mechanics & Engineering. Vol 3, pp.269-289. (1974).

DOI: https://doi.org/10.1016/0045-7825(74)90029-2

[7] Morrison, G. L., Panak, D. L., and DeOtte, R. E., Numerical study of the effects of upstream flow condition upon orifice flow meter performance,. ASME 11th Inter. Conf. on Offshore Mechanics and Arctics Engineering, Calgary, Alberta, Canada, June 7-11, (1992).

DOI: https://doi.org/10.1115/1.2920114

[8] Patankar, V. P., Numerical heat transfer and fluid flow, Mc Graw Hill. (1980).