Experimental Investigation of Retrofitted Extended End-Plate Connections

Abstract:

Article Preview

A series of retrofitted extended end-plate connections have been tested experimentally and evaluated using the component method specified in Eurocode 3. The component method decomposed the end-plate connection into several components, including the tension zone, compression zone, vertical and horizontal shear zone that occurred at the bolt, end-plate, beam and column. Based on the theoretical model, the moment resistance and the initial stiffness of a connection can be predicted. Four experimental tests on the retrofitted extended end-plate connections have been conducted to verify the proposed design method. From the experiment tests, all moment resistance of the connections showed good agreement with theoretical predictions, which establish a reliable foundation to predict the moment resistance of the retrofitted end-plate connection. All initial stiffnesses calculated from theoretical predictions do not represent the actual behaviour of tested connection. All tested connections can be classified as partial strength based on EC 3: Part 1.8, in condition the welding capacity is at least 50% higher than the capacity calculated from the component method.

Info:

Periodical:

Edited by:

Wen-Hsiang Hsieh

Pages:

1330-1333

DOI:

10.4028/www.scientific.net/AMM.284-287.1330

Citation:

P. N. Shek et al., "Experimental Investigation of Retrofitted Extended End-Plate Connections", Applied Mechanics and Materials, Vols. 284-287, pp. 1330-1333, 2013

Online since:

January 2013

Export:

Price:

$38.00

[1] BSI. BS EN 1993-1-8. Eurocode 3: Design of Steel Structures: Design of Joints. London: British Standards Institution (2005).

[2] SCI and BCSA, Joints in Steel Construction. Volume 1: Moment Connections. London, (1996).

[3] L.R.O. de Lima, L. Simoes da Silva, P.C.G. da S. Vellasco, S.A.L. de Andrade. Experimental Evaluation Of Extended Endplate Beam-To-Column Joints Subjected To Bending And Axial Force. Engineering Structures (2004); 26: 1333-1347.

DOI: 10.1016/j.engstruct.2004.04.003

[4] Y.J. Shi, G. Shi, Y.Q. Wang. Experimental and Theoretical Analysis of the Moment-Rotation Behaviour of Stiffened Extended End-Plate Connections. Journal of Constructional Steel Research (2007); 63: 1279-1293.

DOI: 10.1016/j.jcsr.2006.11.008

[5] G. Shi, Y.J. Shi, Y.Q. Wang, M.A. Bradford. Numerical Simulation of Steel Pretensioned Bolted End-Plate Connections of Different Types and Details. Engineering Structures (2008); 30: 2677-2686.

DOI: 10.1016/j.engstruct.2008.02.013

[6] H. Tagawa, S. Gurel. Application of Steel Channels as Stiffeners in Bolted Moment Connections. Journal of Constructional Steel Research (2005); 61: 1650-1671.

DOI: 10.1016/j.jcsr.2005.04.004

[7] B. Bose, A.F. Hughes. Verifying the Performance of Standard Ductile Connections for Semi-Continuous Steel Frames. Proceedings of the Institution of Civil Engineers – Civil Engineering (Structures and Buildings) (1995); 110: 441 – 457.

DOI: 10.1680/istbu.1995.28061

[8] K.M. Abdalla, G.A.R. Abu-Farsakh, S.A. Barakat. Experimental Investigation of Force-Distribution in High-Strength Bolts in Extended End-Plate Connections. Steel and Composite Structures (2007); 7, No. 2: 87 – 103.

DOI: 10.12989/scs.2007.7.2.087

[9] Y.J. Shi, S.L. Chan, Y.L. Wong. Modelling for moment-rotation characteristics for end-plate connections. Journal of Structural Engineering (1996); 122(11): 1300-1306.

DOI: 10.1061/(asce)0733-9445(1996)122:11(1300)

In order to see related information, you need to Login.