Study on Error Compensation of Human Motion Analysis System

Abstract:

Article Preview

Human motion capture system based on a new kind of error compensation technology was developed and used this to assess human motion. On the basis of three-dimensional reconstruction and some essential factors influencing on the measurement accuracy, the measurement error theory and the modified and improved human motion analysis system was established. The experimental data indicate that the measurement precision of the modified and improved system is more precise than the original system on human motion measurement and capturing.

Info:

Periodical:

Edited by:

Zhixiang Hou

Pages:

1149-1153

DOI:

10.4028/www.scientific.net/AMM.48-49.1149

Citation:

H. L. Su and D. W. Zhang, "Study on Error Compensation of Human Motion Analysis System", Applied Mechanics and Materials, Vols. 48-49, pp. 1149-1153, 2011

Online since:

February 2011

Export:

Price:

$38.00

[1] Y.I. Abdel-Aziz and H.M. Karara, in: Direct linear transformation from comparator coordinates into object-space coordinates in close range photogrammetry. Proceeding of the ASP/UI Symposium on Close-Range Photogrammetry[M], Virginia,USA, American Society of Photogrammetry, Falls Church, 1971, 1-18.

DOI: 10.14358/pers.81.2.103

[2] G.A. Wood and R.N. Marshell, in: The accuracy of DLT extrapolation in three-dimensional film analysis[J], submitted to Journal of Biomechanics, 1986, 19(9): 781-785.

DOI: 10.1016/0021-9290(86)90201-0

[3] R.K. Lenz and R.Y. Tsai, in: Techniques for Calibration of the Scale Factor and Image Center for High Accuracy 3-D Machine Metrology[M], IEEE Transactions on Pattern Analysis and Machine Intelligence, 1988, 10(5): 713-720.

DOI: 10.1109/34.6781

[4] Yang nianfeng, Wang jijun etc, in: Influence of Calibration on the Accuracy of 3-D Reconstruction in Direct Linear Transformation Algorithm[J], submitted to Journal of Tsinghua University(Science and Technology), 2000, 40(4): 24-27.

[5] Zhu zhaoguang, Sun hu and Cui bingguang, in: Photogrammetry[M]. Beijing: The Publishing House of Surveying and Mapping, (1995).

[6] Li deren, Wang xinhua, in: Geometrical Calibration of Array Camera[J], submitted to Journal of Wuhan Technical University of Surveying and Mapping, 1997, 22(4): 308-313.

[7] Fang yong, Gao lizhi and Lin zhihang, in: The Research on Calibration Method of Camera Intrinsic Factors in the Intelligent CMM Inspection System[J], submitted to Robot, 1998, 20(2): 148-152.

[8] Kolahi A, Hoviattalab M and Rezaeian T, etc, in: Design of a marker-based human motion tracking system[J], submitted to Biomedical Signal Processing and Control, 2007(2), 59-67.

DOI: 10.1016/j.bspc.2007.02.001

[9] Yang feng and Yuan xiugan, in: Human movement reconstruction from video shot by a single stationary camera[J], submitted to Annals of Biomedical Engineering, 2005, 33(5): 674-684.

DOI: 10.1007/s10439-005-1976-7

[10] Björn Holmberg, in: Towards markerless analysis of human motion[M], Sweden: The Department of Information Technology, Uppsala University, 2005, 19-48.

In order to see related information, you need to Login.