DC MOA Application and Test Technical Analysis

Abstract:

Article Preview

To achieve further optimization of resource utilization, HVDC power transmission project in the proportion of the state grid is growing and the range of applications are more widely. Due to the high cost of converter stations, properly design of DC MOA for DC system insulation coordination and reducing the cost are crucial. Through research and analysis of large amounts of data, applications and test technologies of DC MOA is in-depth expounded, It’s further deepened the staff’s understanding of the DC MOA, there are also some guidance and references to the repair and maintenance of DC MOA.

Info:

Periodical:

Edited by:

Seung-Bok Choi

Pages:

237-242

Citation:

Y. Zhang et al., "DC MOA Application and Test Technical Analysis", Applied Mechanics and Materials, Vol. 737, pp. 237-242, 2015

Online since:

March 2015

Export:

Price:

$38.00

* - Corresponding Author

[1] GB / T 22389-2008 HVDC converter station gapless metal oxide surge arresters guidelines [S] Beijing: Standardization Administration of China, (2008).

[2] GB / T 25083-2010 ± 800kV DC system with MOA [S]. Beijing: Standardization Administration of China, (2010).

[3] DL / T 474. 5-2006 Field insulation test Guide arrester test [S]. Beijing: China Electric Power Press, (2006).

[4] DL / T 377-2010 HVDC equipment acceptance tests [S]. Beijing: China Electric Power Press, (2010).

[5] Q / GDW 111-2004. Handover testing procedures for HVDC converter stations DC electrical equipment [S]. State Grid Corporation, (2004).

[6] Q / GDW 275-2009. ± 800kV DC system electrical equipment handover acceptance test [S]. State Grid Corporation, (2009).

[7] Q / GDW 299-2009. ± 800kV UHVDC equipment preventive testing procedures [S]. State Grid Corporation, (2009).

[8] Che Wenjun CIGRE 34 / 14. 05 HVDC converter stations Guidelines for the use of MOA, describes [J] Power Equipment 2005 (6): 59-62.

[9] WU De-guanl, LIANG Hua—yan92, LIUFan-dongl, QIUKail, Xu Yi, LONG Fang-yul.Testing Methods of MOA at Different Installed Location[J].Insulators and Surge Arresters. 2012(02): 46-49.

[10] CHE Wen-jun, LI Fan. Discussion of Design Mnemonics and Focal Question of Surge Arrester[J]. Insulators and Surge Arresters. 2011(01): 41-45.

[11] Zhao Wanjun , HVDC Engineering Technology [M]. Beijing: China Electric Power Press, (2004).

[12] AN Li. Study of Test Methods of Resistance to Tracking and Erosion o Polymer-Housed Arresters for HVDC Systems and Suggestions for Related Standard Revision[J]. Insulators and Surge Arresters. 2013(02): 99-103.

[13] ZHU Jia-xi, HE Ji-mou, MA Yong-le, LI Pei-bo. Current Distribution Test Methods and Characteristics Research for 1000 kV Surge Arrester [J]. Insulators and Surge Arresters. 2011(04): 39-42.