Experimental and Analytical Study of Various Shear Connectors Used for Cold-Formed Steel-Ferrocement Composite Beam

Abstract:

Article Preview

This work presents the experimental tests carried out to evaluate the behaviour of different types of shear connectors proposed for cold formed steel (CFS) section integrated with ferrocement slab as potential used for composite beam. Ten push-out test specimens of cold-formed steel lipped channel sections connected with ferrocement slab were tested. Three types of shear connectors were studied comprised of bolts, self-drilling-screw and bar angle. The connection behavior is analysed in terms of its load-slip relationship and the failure mode. The parametric studies were performed to investigate the effect on the shear connector’s capacity by varying the number of layers of wire mesh used in ferrocement slab and types of shear connector used. A theoretical analysis (Eurocode 4) was carried out to verify the experiment results. The results show that the experimental and theoretical proved to have good agreement with each other.

Info:

Periodical:

Edited by:

Mohd Mustafa Al Bakri Abdullah, Zarina Yahya, Liyana Jamaludin, Alida Abdullah and Rafiza Abd Razak

Pages:

315-319

DOI:

10.4028/www.scientific.net/AMM.754-755.315

Citation:

A. Saggaff et al., "Experimental and Analytical Study of Various Shear Connectors Used for Cold-Formed Steel-Ferrocement Composite Beam", Applied Mechanics and Materials, Vols. 754-755, pp. 315-319, 2015

Online since:

April 2015

Export:

Price:

$38.00

* - Corresponding Author

[1] AASHTO LRFD Bridge Design Specifications. 3rd ed. Washington (DC): American Association of State Highway and Transportation Officials; (2005).

[2] Ekberg CE, Schuster RM. Floor systems with composite from reinforced concrete slabs. IABSE New York. Final report. 1968. p.385–94.

[3] Porter, Max L., and Carl E. Ekberg Jr. Design recommendations for steel deck floor slabs., Journal of the Structural Division 102, no. ST11 (1976).

[4] Badie SS, Tadros MK, Kakish HF, Splittgerber DL, Baishya MC. Large shear studs for composite action in steel bridge girders. Journal of Bridge Engineering, Vol. 7 (2002), p.195–203.

DOI: 10.1061/(asce)1084-0702(2002)7:3(195)

[5] Culver C, Coston R. Tests of composite beams with stud shear connectors. ASCE Journal of Structural Division Vol. 87 (ST2) (1961), p.1–17.

[6] ASCE. Specification for the design and construction of composite slabs. New York, NY. (1984).

[7] CAN/CSA-S136-01. Cold formed steel structural members. Ontario: National Standard Code of Canada; (2001).

[8] Hanaor A. Tests of composite beams with cold-formed sections. Journal of Constructional Steel Research, Vol. 54 (2000), p.245–264.

DOI: 10.1016/s0143-974x(99)00046-2

[9] Eurocode 4. Design of composite steel and concrete structures: Part 1. 1: General rules and rules for buildings. BS EN 1994-1-1: 2004. British Standards Institution (London); (2004).

DOI: 10.3403/03221508

[10] BS5400. Steel, concrete and composite bridges: Part 5: Code of practice for design of composite bridges. British Standards Institution (London); (1979).

DOI: 10.3403/00073298

In order to see related information, you need to Login.