Comparison of Wind Load Analysis Results Based on Indonesia Minimum Design Loads Standard SNI 1727:2013 Inputted Automatically and Manually by Using SAP2000

Abstract:

Article Preview

This paper presents the results of a comparison study of the internal forces applied to the structure due to wind load determined based on SNI 1727: 2013 that is inputted manually and automatically using ASCE 7-10 wind load feature in SAP2000. The wind load reviewed in this study is the wind load that calculated by following the Directional Procedure stated in SNI 1727:2013. The study shows that the wind load calculated based on SNI 1727:2013 when the internal pressure coefficient GCpi is defined as 0.18 is 12% higher than the wind load calculated automatically by applying ASCE 7-10 wind load feature provided by SAP2000 when the wind parameters are assigned based on SNI 1727:2013.

Info:

Periodical:

Edited by:

Djoko Legono, Radianta Triatmaja, Prof. Priyosulistyo, Veerasak Likhitruangsilp, Lim Pang Zen, Teuku Faisal Fathani, Ali Awaludin, Intan Supraba, Imam Muthohar, Dr. Endita, Fikri Faris and Dr. Inggar Septhia Irawati

Pages:

132-141

Citation:

O. T. Handayani et al., "Comparison of Wind Load Analysis Results Based on Indonesia Minimum Design Loads Standard SNI 1727:2013 Inputted Automatically and Manually by Using SAP2000", Applied Mechanics and Materials, Vol. 881, pp. 132-141, 2018

Online since:

May 2018

Export:

Price:

$38.00

* - Corresponding Author

[1] American Society of Civil Engineers, ASCE 7-10 Minimum Design Loads for Buildings and Other Structures, Virginia, (2010).

[2] Concrete Committee of Japan Society of Civil Engineers, Standard Specification for Concrete Structures-2007 Design,, JSCE 2010 Concrete Committee, Tokyo, (2010).

[3] National Standardization Agency, SNI 1727: 2013 - Minimum Load for The Design Of Buildings and Other Structures (in Indonesia), BSN, Jakarta, (2013).

[4] Department of Public Works, Guidelines for Planning for Houses and Buildings (in Indonesia), SKBI – 1.3.53, Department of Public Works, Jakarta, (1987).

[5] Computer & Structures Inc., Introductory Tutorial for SAP 2000, Linear and Nonlinear Static and Dynamic Analysis and Design of Three-Dimensional Structures, Computer & Structures Inc., California, (2011).

[6] I. Satyarno, P. Nawangalam, I. Pratomo, Study SAP2000 Series 2 (in Indonesia), Zamil Publishing, Yogyakarta, (2012).

[7] R.W. Rudiatmoko, N.M.A. Wiryasa, I.A.M. Budiwati, Design of reinforced concrete building structures using special moment resisting frame system (SPRMK) with RSNI 03-1726-xxxx (in Indonesia), Jurnal Ilmiah Elektronik Infrastruktur Teknik Sipil. (2012).

[8] W. Dewobroto, Design of reinforced concrete blocks using SAP2000 (in Indonesia), Jurnal Teknik Sipil – UPH. 1(2) (2005) 1-15.

[9] M. Khallaf, J. Jupp, Performance-based Design of Tall Building Envelopes using Competing Wind Load and Wind Flow Criteria, Procedia Engineering 180 (2017) 99-109.

DOI: https://doi.org/10.1016/j.proeng.2017.04.169

[10] B. Natalini, M. B. Natalini, Wind loads on buildings with vaulted roofs and side walls – A review, Journal of Wind Engineering & Industrial Aerodynamics 161 (2017) 9-16.

DOI: https://doi.org/10.1016/j.jweia.2016.12.004