Abstract:

Article Preview

The designs of hip joint prostheses have an influence on both the quality of the metal–bone cement contact and the failure rate of the cement mantle. The designers of implant systems must confront biomaterial and biomechanical problems, including in vivo forces on implants, load transmission to the interface, and interfacial tissue response. Cement spacers are being increasingly used for revision arthroplasties. In this study, a three-dimensional finite elements method is used to analyse the mechanical behaviour of the reinforced spacer out of the bone cement (PMMA) by computing the maximum stress. One of the most important factors in the reinforce design is to reduce the stress on the bone cement and the femur. The static load analysis is based, by selecting the peak load during the normal walking activity. Results show that, Von Mises stress is significantly reduced in the cement bone of full-stem and rod reinforced spacers.

Info:

Periodical:

Edited by:

Hao Gong and K.M. Gupta

Pages:

36-40

Citation:

M.M. Bouziane et al., "Finite Element Analysis of the Mechanical Behaviour of a Reinforced PMMA-Based Hip Spacer", Advanced Materials Research, Vol. 1105, pp. 36-40, 2015

Online since:

May 2015

Export:

Price:

$38.00

* - Corresponding Author

[1] Deshmukh RJ, Thevarajan K, Kok CS, Sivapathasundaram N, George SV. An intramedullary: cement spacer in total hip arthroplasty. Journal of Arthroplasty (1998) Feb; 13(2) 197-9.

DOI: https://doi.org/10.1016/s0883-5403(98)90099-7

[2] Rajesh Botchu, R. Anwar, KJ Ravikumar. Fractured cement spacers—a report of two cases. The Iowa Orthopaedic Journal (2009) Volume 29 17-18.

[3] T. Thielen, S. Maas, A. Zuerbes, D. Waldmann, K. Anagnostakos, J. Kelm. Development of a reinforced PMMA-based hip spacer adapted to patients' needs. Medical Engineering & Physics 31 (2009) 930–936.

DOI: https://doi.org/10.1016/j.medengphy.2009.05.004

[4] Brekelmans W, Poort H, Sloof T A new method to analysethe mechanical behavior of skeletal parts. Acta Orthop Scand 43: (1972) 301–17.

[5] Oguz K, Bulent E The effects of static, dynamic and fatigue behavior on three-dimensional shape optimization of hip prosthesis by finite element method (2007) 2269-2277.

DOI: https://doi.org/10.1016/j.matdes.2006.08.012

[6] Bergmann, G., 2001, HIP98, Free University, Berlin, ISBN 3-9807848-0-0.

[7] G.N. Duda et al: Influence of Muscle Forces on Femoral Strain Distribution. Journal of Biomechanics (1998), Vol. 31, pp.841-846.

[8] A. Rohlmann et al: Finite element analysis and experimental investigation in a femur with hip endoprosthesis. Journal of Biomechanics (1983) Vol 16, 727–742.

DOI: https://doi.org/10.1016/0021-9290(83)90082-9

[9] Hsieh P-H, Chen L-H, Chen C-H, Lee MS, Yang W-E, Shih C-H. Two-stage revision hip arthroplasty for infection with a custom-made, antibiotic-loaded, cement prosthesis as an interim spacer. J Trauma Injury Infect Crit Care (2004); 56: 1247–52.

DOI: https://doi.org/10.1097/01.ta.0000130757.53559.bf

[10] Leunig M, Chosa E, Speck M, Ganz R. A cement spacer for two-stage revision of infected implants of the hip. Int Orthop (1998); 22: 209–14.

DOI: https://doi.org/10.1007/s002640050244

[11] Meani E, Romanò C, Crosby L, Hofmann G. Infection and local treatment in orthopedic surgery. Berlin: Springer Verlag; (2007).

DOI: https://doi.org/10.1007/978-3-540-47999-4

[12] Carrero V, Honl M. Mechanischer Test eines Knochenzementspacers für die Revisionshüftendoprothetik. DePuy Prüftestbericht (2000).

[13] Baleani M, Traina F, Toni A. The mechanical behaviour of a pre-formed hip spacer. Hip Int (2003); 13: 159–62.

[14] Schoellner C, Fuerderer S, Rompe JD, Eckardt A. Individual bone cement spacers (IBCS) for septic hip revision—preliminary report. Arch Orthop Trauma Surg (2003); 123: 254–9.

DOI: https://doi.org/10.1007/s00402-003-0502-3

Fetching data from Crossref.
This may take some time to load.