Numerical Study on Effects of Molten Steel Flow about Different Blowing Argon Position in Ladle Furnace

Abstract:

Article Preview

Based on momentum theorem, principle of mass conservation, and some experimental formulas, the distribution of velocity in ladle furnace was calculated by CFD methods. Blowing argon arrangement in ladle furnace is researched, through comparing 13 schemes about blowing argon arrangement, some conclusions are obtained. When there is only a blowing argon in ladle furnace, the better scheme is that the distance from center of LF bottom to the hole is 0.7r. When there are two blowing argon in ladle furnace, the better scheme is that the angle of two holes is 60°~90°and distance from center to blowing argon hole is 0.5r~0.7r.

Info:

Periodical:

Advanced Materials Research (Volumes 146-147)

Edited by:

Sihai Jiao, Zhengyi Jiang and Jinglong Bu

Pages:

1031-1037

DOI:

10.4028/www.scientific.net/AMR.146-147.1031

Citation:

Y. S. Chen et al., "Numerical Study on Effects of Molten Steel Flow about Different Blowing Argon Position in Ladle Furnace", Advanced Materials Research, Vols. 146-147, pp. 1031-1037, 2011

Online since:

October 2010

Export:

Price:

$35.00

In order to see related information, you need to Login.