Application of Monitoring Technology Based on Aeolian Vibration in Smart Grid

Abstract:

Article Preview

The aeolian vibration of overhead transmission lines frequently brings about the breaking fatigue of wires, which makes a serious threat to the security of transmission lines.Today, more and more attentions have been paid to the aeolian vibration both in research and commercial realms . As aeolian vibration monitoring can accurately monitor wire damage, it is conducive to timely maintenance and avoiding accidents. In our paper, we propose a system model adopting bending amplitude method to estimate bending amplitude, calculate dynamic bending strain of wire and obtain early warning tips by comparing with strain chart based on the research of principles of aeolian vibration. Besides, A prototype system is developed to realize the effectiveness of the proposed model.

Info:

Periodical:

Advanced Materials Research (Volumes 341-342)

Edited by:

Liu Guiping

Pages:

672-677

Citation:

G. Ma et al., "Application of Monitoring Technology Based on Aeolian Vibration in Smart Grid", Advanced Materials Research, Vols. 341-342, pp. 672-677, 2012

Online since:

September 2011

Authors:

Export:

Price:

$38.00

[1] H.T. Zhang. Examples of Aedian Vibration Harmfulness on O verhead Transmission Lines and Importance of its F ield Measurement. Power Construction. 5 (1997) 38-40.

[2] J. Chen, Z.J. Huang, L.P. Li, F.H. Jin. Fretting damage characteristics of overhead electrical conductors. China Power. 37 (2004) 31-33.

[3] J. Vecchiarelli, I.G. Currie, D.G. Havard. Computational Analysis·of Aeolian Conductor Vibration With a Stockbridge Type Damper. Journal of Fluids and Structures. 14 (2000) 489-509.

DOI: https://doi.org/10.1006/jfls.1999.0279

[4] ZH.P. Liang, C. Wang, D.Y. Kong, L. Li. Analysis of Aeolian Vibration Influence Factors on UHV Transmission Conductor. Water Resources and Power, 26(2008) 185-188.

[5] H. Wang, Y.B. Liu, Y.M. Dong, H. Xu. The Study of Conductor Fatigue Test Amplitude of Overhead Lines. Proceedings of the CSEE. 28 (2008) 123-128.

[6] D.M. Yu, X.Y. Guo, F.D. Chen. Application of on-line monitoring system for 500 kV transmission lines in North China. China Power, 42 (2009) 53-56.

[7] H. Wang, Y.B. Liu, J.C. Wang, H. Xu, D. ZH. Cao. Application of Anti-vibration Aid-design Expert System for Long-span Overhead Line. Proceedings of the CSEE., 30 (2010) 99-104.

[8] H.W. Liu, J.F. Li, CH.F. Wang. Research and Application of On-line Monitoring Management Platform for 1000 kV AC Transmission Lines. Automation of Electric Power Systems. 33 (2009) 98-102.

[9] H.B. Chen, CH. Wang, J.F. Li, G.Q. Xu. Application of On-line Monitoring Technologies for UHV AC Transmission Lines. Power System Technology. 33 (2009) 55-58.

[10] ZH.D. Wang . Von Karman and Karman vortex street. Nature, 32 (2010) 243-245.

[11] Y. Gu, Process of the Fatigue Damage Cumulative Rules of FRP. Advances in Mechanics. 31 (2001) 193-202.