Studies on the Grid-Connected Characteristics about Large-Scale Photovoltaic Power Station in Weak Grid Systems

Abstract:

Article Preview

This paper made some researches of modeling on the systems of the large-scale photovoltaic(PV) power station, and established the PV model, the rectifier and inverter circuits and so on. Using MATLAB and PSASP, simulation and analysis of grid-connected characteristics about the large-scale PV power station in weak grid systems were carried out, focusing on the transient stability in the fault condition of the line-side and the power quality. These two simulation results had good consistency, which demonstrated the accuracy of the large-scale PV power station model in this paper and the analysis of its grid-connected characteristics. The conclusion of this paper will provide some theoretical basis of improving the stability of grid-connected and reducing the harmonic current in weak grid systems, and will also provide some theoretical basis and the guide of grid-connected for the new energy strategy of our country in the future.

Info:

Periodical:

Advanced Materials Research (Volumes 347-353)

Edited by:

Weiguo Pan, Jianxing Ren and Yongguang Li

Pages:

639-646

DOI:

10.4028/www.scientific.net/AMR.347-353.639

Citation:

H. Jiang et al., "Studies on the Grid-Connected Characteristics about Large-Scale Photovoltaic Power Station in Weak Grid Systems", Advanced Materials Research, Vols. 347-353, pp. 639-646, 2012

Online since:

October 2011

Export:

Price:

$35.00

[1] Shen Hui, Shu Bifen, Wen Lishi. The development opportunity and strategic countermeasure of solar energy photovoltaic industry in China(In Chinese) [J]. Battery Bimonthly,2005(06):28-29.

[2] Zhao Yuwen.Discussion on the Trend of Solar PV Industry in Our Country(In Chinese) [J].China Construction Dynamics(Solar & Renewable Energy Sources),2004(02):43-46.

[3] Zhang Yaoming.The Current Status and Prospects of solar photovoltaic industry in China(In Chinese) [J] .Energy Research & Utilization,2007, (01):27-28.

[4] Zhou Dejia, Zhao Zhengming, Yuan Liqiang, Feng Bo. Optimum Control and Stability Analysis for a 300kW Photovoltaic Grid-Connected System(In Chinese) [J]. Transactions of China Electrotechnical Society, 2008,23(11):44-46.

[5] Zue A.O.,A. Chandra. Simulation and stability analysis of a 100 kW grid connected LCL photovoltaic inverter for industry [C]. Power Engineering Society General Meeting. IEEE, 2006,: 6.

DOI: 10.1109/pes.2006.1709455

[6] Hwang I H, Ahn K S, Lim H C. Design, development and performance of a 50KW Grid-connected PV system with three phase current-controlled inverter[C]. PhotovoltaicSpecialists Conference. 2000, 1664—1667.

DOI: 10.1109/pvsc.2000.916221

[7] MAO Hongsheng, MAO Xingkui, PEI Changsheng. Simulation and Research of Single-phase Grid-connected Photovoltaic Inverter Based on Simulink[J]. Low Voltage Apparatus, 2011, 10(06): 50-52.

[8] Wang Fei, Yu Shijie, Su Jianhui, Shen Yuliang, Wang Haining. Study and Realization of Photovoltaic Grid-connected Power System[J]. Acta Energiae Solaris Sinica, 2005, 11(05): 15-18.

[9] Xiong Yuansheng. Research on control problems of solar photovoltaic generation system(In Chinese). Zhejiang: Zhejiang university of technology.

[10] Zhao Wei. Research on Grid-Connected Photovoltaic System(In Chinese). Anhui: Hefei university of technology.