A Fault Diagnosis Method Based on Improved Grey Correlation Grade for Turbine Generator Unit

Abstract:

Article Preview

Analyzing grey correlation grade method, a fault diagnosis method of improved grey correlation grade is presented for turbine generator unit. The method calculates weight according to test sample, and then calculates the weighted grey correlation grade. And for the characteristics of turbine generation unit, a fault diagnosis method based on improved grey correlation grade is presented. Simulation results show that the proposed method can successfully diagnose all fault of turbine generation unit, and fault isolation capability is much stronger than traditional grey relation.

Info:

Periodical:

Advanced Materials Research (Volumes 383-390)

Edited by:

Wu Fan

Pages:

5045-5049

DOI:

10.4028/www.scientific.net/AMR.383-390.5045

Citation:

C. M. Xu et al., "A Fault Diagnosis Method Based on Improved Grey Correlation Grade for Turbine Generator Unit", Advanced Materials Research, Vols. 383-390, pp. 5045-5049, 2012

Online since:

November 2011

Export:

Price:

$35.00

In order to see related information, you need to Login.