The Fuzzy Immune PID Control Based on the Water Position of the Steam Generator

Abstract:

Article Preview

In this paper, through a series of experiments in steam generator, which located in the simulation platform of nuclear power, the model of the water position of the Nuclear Steam generator is concluded. Comparing with traditional PID control, adoption of fuzzy immune control strategies gets better results. The thesis also verifies the excellent self-adaptive ability the fuzzy immune PID control possesses.

Info:

Periodical:

Advanced Materials Research (Volumes 383-390)

Edited by:

Wu Fan

Pages:

7503-7508

DOI:

10.4028/www.scientific.net/AMR.383-390.7503

Citation:

Y. Xue and T. Wang, "The Fuzzy Immune PID Control Based on the Water Position of the Steam Generator", Advanced Materials Research, Vols. 383-390, pp. 7503-7508, 2012

Online since:

November 2011

Authors:

Export:

Price:

$35.00

[1] DUAN Suzhen, ZHANG Naiyao, CUI Zhenhua. Fuzzy controller design method for PWR steam generator level control. J T singhua Univ(Sci&Tech), 2006, Vol 46, No. 9.

[2] MA Zhicai, ZHENG Mingguang, FANG Zhou, MA Xusheng. Fuzzy Control of Water Level in NPP Steam Generators at Low Level Operation. Nuclear Safety. No. 4. (2005).

[3] SONG Mei-cun, ZHANG Yu-sheng. The fuzzy adaptive PID control on water position of the steam generator. SHIP&OCEAN ENGINEERING. Vol. 36 No. 5 Oct. (2007).

[4] Liu Jinkun. Simulation of the Advanced PID Control Strategies based on Matlab(Edition 2). Beijing. Electronic Industry Press , (2004).