Research on Application of Synchronized Phasor Measurement Unit (PMU) for Smart Substation

Abstract:

Article Preview

Synchronized phasor measurement unit (PMU) has become the important monitoring device in power networks for high precision and accurate time tag of measurement data. This paper presents the PMUs suitable for smart substation which adopt embedded software-hardware platform. The differences between the common PMUs and PMUs for smart substation are introduced, and the software modules design is put forward, too. The key technology of PMUS is introduced including receiving and processing of sampling data message based on IEC 61850 standard and phasor calculation based on discrete Fourier transform.

Info:

Periodical:

Advanced Materials Research (Volumes 860-863)

Main Theme:

Edited by:

Qunjie Xu, Yongguang Li and Xiu Yang

Pages:

1842-1845

Citation:

W. Zheng et al., "Research on Application of Synchronized Phasor Measurement Unit (PMU) for Smart Substation", Advanced Materials Research, Vols. 860-863, pp. 1842-1845, 2014

Online since:

December 2013

Export:

Price:

$38.00

* - Corresponding Author

[1] Zhuang Liming, Qi Hongwei: Application of synchronous phasormeasurement technology to bay levels of substations[J]. East ChinaElectric Power, 2006, 34(10): 90-92(in Chinese).

[2] IEC. IEC 61850-7-4—2003 Communication networks and systems in substations[S]. Geneva:IEC, (2003).

[3] Chen Li, Jiao Jile, Deng Chengyu, et al: Research and implementation of simplified MMS sending procedure for embedded systems[J]. Application of Computer, 2009(8): 93-96(in Chinese).

[4] Xu Kunyao, Fan Zhaoyong, Zhao Weijuan, et al. Application of sampled value transmission based on IEC 61850[J]. Proceedings of the CSU-EPSA, 2009, 21(6): 107-111(in Chinese).

[5] Liao Zeyou, Guo Yun, Yang Huihong: The summary and contrastive analysis of sampled values transmission communication protocol in digital substations[J]. Power System Protection and Control, 2010, 38(4): 113-118(in Chinese).

[6] Li Gang, Wang Qingping, Ge Weichun, et al: Application of Ethernet in digitalized substation[J]. Power System Technology, 2008, 32(S2): 142-145(in Chinese).

[7] Yang Nianci, Jiang Huilan, Gong Dade, et al: The influence of power system frequency deviation on Fourier algorithm[J]. Journal of Tianjin University, 1993(5): 9-16(in Chinese).

[8] Zhou Bin, Lu Guogang, Huang Guofang, et al: A sampled values interface method for substation IED based on the linear Lagrange interpolation algorithm[J]. Automation of Electric Power Systems, 2007, 31(3): 86-90(in Chinese).

Fetching data from Crossref.
This may take some time to load.