An ultra-high vacuum apparatus was developed for the measurement of H permeation through metal membranes. The H permeation was measured for pressures ranging from 0.1 to 100mbar, and temperatures ranging from 50 to 440C. The activation enthalpy for permeation was equal to 0.382eV.

Hydrogen Permeability Measurements of Pd, Ni and Fe Membranes. K.Yamakawa, M.Ege, B.Ludescher, M.Hirscher, H.Kronmuller: Journal of Alloys and Compounds, 2001, 321[1], 17-23