By using a radiotracer sectioning technique, the diffusivity of Ni in 2 high-Cr steels was studied at 1050 to 1200C. The steels contained 0.15%C, 1%Si and 0.80%Mn, and enough Ti to bind the free C. The results could be described by:

17%Cr:     D (cm2/s) = 1.44 x 100 exp[-67.0(kcal/mol)/RT]

25%Cr:     D (cm2/s) = 2.17 x 102 exp[-70.2(kcal/mol)/RT]

S.V.Zemskii, L.S.Makashova, S.A.Golovanenko: Izvestiya Vysshikh Uchebnykh Zavedenii Chernaya Metallurgiya, 1974, 8, 99-102

 

Table 64

Bulk Diffusion of 99Mo in Fe-Cr Alloys

 

Cr (wt%)

Temperature (K)

D (m2/s)

8.07

1103

2.01 x 10-15

8.07

1043

2.80 x 10-16

8.07

983

7.23 x 10-17

8.07

923

4.69 x 10-18

8.07

863

3.63 x 10-19

8.07

803

3.38 x 10-20

10.18

1103

2.28 x 10-15

10.18

1043

3.77 x 10-16

10.18

983

4.00 x 10-17

10.18

923

2.80 x 10-18

10.18

863

6.26 x 10-20

10.18

803

3.22 x 10-20

12.25

1103

1.96 x 10-15

12.25

1043

4.64 x 10-16

12.25

983

4.80 x 10-17

12.25

923

4.50 x 10-18

12.25

863

7.09 x 10-20

12.25

803

3.15 x 10-20

8.03

983

5.37 x 10-17

8.03

923

1.03 x 10-18

8.03

863

1.20 x 10-19

8.03

803

4.55 x 10-20

8.36

983

6.95 x 10-17

8.36

923

1.35 x 10-18

8.36

863

3.38 x 10-20

8.36

803

1.44 x 10-20

8.50

983

6.84 x 10-17

8.50

923

2.62 x 10-18

8.50

863

2.93 x 10-20

8.50

803

1.74 x 10-20

Table 65

Grain Boundary Diffusion of 99Mo in Fe-Cr Alloys

 

Cr (wt%)

Temperature (K)

D (m3/s)

8.07

1103

1.82 x 10-21

8.07

1043

3.08 x 10-22

8.07

983

1.28 x 10-22

8.07

923

3.74 x 10-23

8.07

863

2.24 x 10-24

8.07

803

1.72 x 10-25

10.18

1103

1.15 x 10-21

10.18

1043

3.28 x 10-22

10.18

983

1.10 x 10-22

10.18

923

6.47 x 10-23

10.18

863

1.87 x 10-24

10.18

803

7.72 x 10-26

12.25

1103

1.10 x 10-21

12.25

1043

5.29 x 10-22

12.25

983

8.44 x 10-23

12.25

923

2.56 x 10-23

12.25

863

1.83 x 10-24

12.25

803

1.93 x 10-25

8.03

983

2.27 x 10-22

8.03

923

5.26 x 10-23

8.03

863

4.52 x 10-24

8.03

803

2.43 x 10-25

8.36

983

5.39 x 10-23

8.36

923

1.33 x 10-23

8.36

863

6.96 x 10-25

8.36

803

5.09 x 10-26

8.50

983

1.86 x 10-23

8.50

923

7.93 x 10-24

8.50

863

8.68 x 10-25

8.50

803

9.54 x 10-26

 

Table 66

Lattice Diffusion Parameters for 22P in Fe-Cr

 

P (at%)

Cr (at%)

Phase

Do (m2/s)

E (kJ/mol)

-

-

paramagnetic

2.87 x 10-2

271

-

-

ferromagnetic

1.38 x 101

332

0.16

-

paramagnetic

3.76 x 10-2

275

0.16

-

ferromagnetic

1.08 x 10-1

288

0.18

-

paramagnetic

2.55 x 10-3

247

0.18

-

ferromagnetic

1.06 x 103

359

0.38

-

paramagnetic

8.87 x 10-3

259

0.38

-

ferromagnetic

4.90 x 100

316

0.15

1.10

paramagnetic

1.07 x 10-2

265

0.15

1.10

ferromagnetic

3.36 x 10-1

296