Manometric measurements were used to study the permeation of H through medium alloy steel, with and without the addition of 0.5wt%Pd. Measurements were also made of H solubility, and this permitted the calculation of diffusion coefficients (table 167).

V.I.Arkharov, T.T.Moroz, I.A.Novokhatskii, M.I.Eremina, S.I.Khokhlova: Fiziko-Khimicheskaya Mekhanika Materialov, 1971, 7[6], 51-4

 

Table 162

Ternary Interdiffusion Coefficient, DCrCrFe, for the Fe-Ni-Cr System at 1223K

 

Ni (wt%)

Cr (wt%)

Value (m2/s)

70.3

17.8

9.2 x 10-16

71.3

19.6

1.15 x 10-15

64.8

5.9

1.50 x 10-15

66.6

11.6

1.08 x 10-15

75.9

23.6

-3.30 x 10-15

42.0

23.0

5.70 x 10-15

54.0

24.0

2.40 x 10-15

83.6

13.2

4.50 x 10-15

continued

 

Table 162 (continued)

Ternary Interdiffusion Coefficient, DCrCrFe, for the Fe-Ni-Cr System at 1223K

 

Ni (wt%)

Cr (wt%)

Value (m2/s)

91.9

1.8

3.6 x 10-15

58.1

24.2

2.77 x 10-15

63.7

24.5

3.03 x 10-15

67.4

24.4

2.19 x 10-15

75.4

24.4

3.41 x 10-15

54.8

25.9

1.50 x 10-15

46.5

9.0

3.00 x 10-15

49.2

15.3

3.70 x 10-15

45.0

28.4

1.30 x 10-15

57.0

28.8

8.0 x 10-16

59.0

30.0

2.5 x 10-16

42.0

9.8

2.83 x 10-15

35.4

18.5

5.50 x 10-15

42.4

29.6

4.30 x 10-15

43.9

9.5

4.40 x 10-15

43.4

16.6

6.30 x 10-15

45.1

5.8

5.40 x 10-15

42.3

28.5

3.70 x 10-15

44.7

4.5

3.40 x 10-15