Diffusion through a membrane was studied at temperatures of up to 600C. It was found that the results could be described by:
D (cm2/s) = 1.8 x 10-1exp[-14.8(kcal/mol)/RT]
Determination of Deuterium Surface Recombination Rates on Stainless Steel. M.Braun, B.Emmoth, F.Waelbroeck, P.Wienhold: Journal of Nuclear Materials, 1980, 93-94, 861-5
Table 60
Permeation Parameters for H (0.1MPa)
in Stainless Steels at 200 to 430C
Steel | Po (molH2/msMPa½) | E (kJ/mol) |
AISI 316L | 3.90 x 10-4 | 64.06 |
AISI 316LN | 1.85 x 10-4 | 60.66 |
21-6-9 | 2.52 x 10-4 | 61.29 |
21-9-9 | 2.83 x 10-4 | 62.29 |
AISI 304 | 2.85 x 10-4 | 62.43 |
AISI 321 | 2.44 x 10-4 | 62.70 |