It was shown that permeation through the walls of Pd-5.9wt%Ni alloy tubes, under a gradient-less pressure of H, was directly proportional to the difference between the square roots of the partial pressures of H at the entrance and at exit of the tube. The data, for temperatures of 113 to 306C, could be described by:

P (cm mm/s atm½) = 0.2 exp[-6.0(kcal/mol)/RT]

L.F.Pavlova, V.M.Gryaznov, V.B.Khlebnikov, N.K.Borovkova: Doklady Akademii Nauk, 1972, 207[4], 919-22

 

Table 152

Parameters for H Diffusion in Pd-Rh

 

Rh (at%)

Do (m2/s)

E (kJ/mol)

0

2.89 x 10-7

22.19

3

3.95 x 10-7

23.54

6

4.22 x 10-7

24.15

8

4.35 x 10-7

25.03

10

6.49 x 10-7

26.59

15

4.89 x 10-7

27.45

21

8.18 x 10-7

31.27

26

5.62 x 10-7

32.24

33

5.83 x 10-7

35.10