Gas chromatography used to monitor the diffusion of H through a tube which was filled with liquid Fe or Fe-Ni alloys. The H concentration profile which existed in the melt upon attaining steady-state H diffusion was also determined. Diffusion data (table 74) were calculated from the results.
S.Maekawa, K.Taniguchi: Proceedings of the International Conference on the Science and Technology of Iron and Steel, September 1970, Section 3, 559-61
Table 74
Diffusivity of H in Liquid Fe and Fe-Ni
Ni (wt%) | Temperature (C) | D (cm2/s) |
0 | 1560 | 7.5 x 10-4 |
0 | 1580 | 8.0 x 10-4 |
10 | 1530 | 1.23 x 10-3 |
10 | 1560 | 1.35 x 10-3 |
10 | 1580 | 1.46 x 10-3 |
20 | 1500 | 2.22 x 10-3 |
20 | 1530 | 2.30 x 10-3 |
20 | 1560 | 2.45 x 10-3 |
20 | 1580 | 2.61 x 10-3 |