The migration of H through a maraging steel was studied, at temperatures of between 373 and 590C, by using an ultra-high vacuum quadrupole mass spectrometry method and an input gas pressure of about 0.1MPa. The permeation parameters (table 75) were determined as a function of the aging time.

D.P.Yao, W.X.Chen, X.K.Sun, J.Xu: Scripta Metallurgica, 1988, 22[5], 611-5

 

 

 

Table 75

Permeation Parameters for Maraging Steel

 

Aging Time (h)

P (mol/msPa½)

E (kJ/mol)

0

0.00147

41.9

1

0.00115

42.2

3

0.00142

43.3

5

0.00411

38.8