The penetration of H into single-phase a-phase solid solutions which contained up to 10%V was studied at 300 to 700C. It was found that changes in the V concentration, from 0 to 5%, did not affect the penetration of H. A further increase in the V concentration increased the temperature coefficient of H penetration and the activation energy (table 82).
V.I.Zhitenev, R.A.Ryabov, V.M.Slesarev, P.V.Geld: Izvestiya Vysshikh Uchebnykh Zavedenii (Fiz.), 1976, 19[11], 144-6
Table 82
Parameters for the Permeation of H in a-Phase Fe-V
V (wt%) | Po (cm/mm-s-atm½) | E (kcal/g-atom H) |
0 | 2.17 | 8.45 |
1.99 | 2.29 | 8.53 |
5.00 | 2.68 | 8.86 |
6.89 | 3.55 | 9.62 |
10.0 | 6.64 | 10.8 |