The diffusion of B at temperatures of between 900 and 1200C was measured by means of particle tracking auto-radiography (tables 69 and 70). It was found that the B diffusivity in -Fe increased as Ni was added.

W.Wang, S.Zhang, X.He: Acta Metallurgica et Materialia, 1995, 43[4], 1693-9

 

 

 

Table 69

Diffusivity of B in Various Alloys

 

Material

Temperature (C)

D (m2/s)

04MnNb

954

4.860 x 10-12

04MnNb

1003

7.324 x 10-12

04MnNb

1056

1.075 x 10-11

04MnNb

1104

1.530 x 10-11

04MnNb

1154

2.318 x 10-11

04MnNb

1204

2.996 x 10-11

Fe-30%Ni

954

2.330 x 10-11

Fe-30%Ni

1003

3.732 x 10-11

Fe-30%Ni

1056

5.859 x 10-11

Fe-30%Ni

1104

7.898 x 10-11

Fe-30%Ni

1154

1.172 x 10-10

Fe-30%Ni

1204

1.597 x 10-10

Ni

950

5.021 x 10-11

Ni

1003

7.592 x 10-11

Ni

1056

1.088 x 10-10

Ni

1097

1.366 x 10-10

Ni

1154

1.947 x 10-10

Ni

1201

2.566 x 10-10

25MnTi

950

2.801 x 10-12

25MnTi

1001

4.424 x 10-12

25MnTi

1097

8.779 x 10-12

25MnTi

1147

1.388 x 10-11

25MnTi

1201

1.866 x 10-11

Fe-3%Si

904

1.694 x 10-11

Fe-3%Si

954

2.613 x 10-11

Fe-3%Si

1003

3.639 x 10-11

Fe-3%Si

1056

4.879 x 10-11

Fe-3%Si

1104

6.445 x 10-11

 

 

 

Table 70

Parameters for B Diffusion in Various Alloys

 

Material

Do (m2/s)

Q (kcal/mol)

04MnNb

2.6 x 10-7

26.5

Fe-30%Ni

1.9 x 10-6

27.5

Ni

6.6 x 10-7

23.0

25MnTi

2.0 x 10-7

27.2

Fe-3%Si

1.5 x 10-7

21.2