Computer Assisted Orthopaedic Surgery in Total Hip Arthroplasty with Alumina Alumina Pairing

Abstract:

Article Preview

Info:

Periodical:

Key Engineering Materials (Volumes 240-242)

Main Theme:

Edited by:

Besim Ben-Nissan, Doron Sher, William Walsh

Pages:

843-846

Citation:

R. Schmidt et al., "Computer Assisted Orthopaedic Surgery in Total Hip Arthroplasty with Alumina Alumina Pairing", Key Engineering Materials, Vols. 240-242, pp. 843-846, 2003

Online since:

May 2003

Export:

Price:

$38.00

[1] Bader R, Willmann G, Ceramic acetabular cups for hip endoprostheses. 7: How do position of the center of rotation and the CCD angle of the shaft modify range of motion and impingement? Biomed Tech 44 (1999): pp.345-351.

DOI: https://doi.org/10.1515/bmte.1999.44.12.345

[2] Standardization committee of the International Society of Biomechanics (2001) Standard for hip joint coordinate system. http: /isb. ri. ccf. org/standards/hip. pdf.

[3] Bader R, Willmann G, Ceramic cups for hip endoprostheses. 6: Cup design, inclination and antetorsion angle modify range of motion and impingement. Biomed Tech 44 (1999): pp.212-219.

DOI: https://doi.org/10.1515/bmte.1999.44.7-8.212

[4] Bartz RL, Noble PC, Kadakia NR, Tullos HS, The effect of femoral component head size on posterior dislocation of the artificial hip joint. J Bone Joint Surg Am 82 (2000): pp.1300-7.

DOI: https://doi.org/10.2106/00004623-200009000-00010

[5] Murray DW, The definitions and measurement of acetabular orientation. J Bone Joint Surg Br 75 (1993), pp.228-232.

[6] Coventry J, Late dislocation in patients with Charnley total hip arthroplasty. J Bone Joint Surg Am 67 (1985): pp.832-41.

[7] Charnley J, Total hip replacement by low-friction arthroplasty. Clin Orthop 72 (1970): pp.7-21.

[8] Harris WH, Advances in surgical technique for total hip replacement: without and with osteotomy of the greater trochanter. Clin. Orthop 146 (1980): pp.188-204.

DOI: https://doi.org/10.1097/00003086-198001000-00026

[9] Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR, Dislocations after total hip replacement arthroplasties. J Bone Joint Surg Am 60 (1978): pp.217-20.

DOI: https://doi.org/10.2106/00004623-197860020-00014

[10] Seki M, Yuasa N, Ohkuni K, Analysis of optimal range of socket orientations in total hip arthroplasty with use of computer-aided design simulation. J Orthop Res 16 (1998): pp.513-7.

DOI: https://doi.org/10.1002/jor.1100160418

[11] DiGioia AM, Jaramaz B, Blackwell M, Simon A, Morgan F, Moody E, Nikou C, Colgan D, Aston A, Labarca RS, Kischell E, Kanade T, The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment. Clin Orthop 355 Suppl (1998).

DOI: https://doi.org/10.1097/00003086-199810000-00003

[12] DiGioia A, Moody JE, Jaramaz B, LaBarca RS, Nikou C (2001) Acetabular Component orientation using surgical navigation technologies. Proceedings of the 68th Annual AAOS Meeting, San Fransisco, PE329.