The Influence of Boundary Conditions on Finite Element Analysis

Abstract:

Article Preview

Info:

Periodical:

Key Engineering Materials (Volumes 240-242)

Main Theme:

Edited by:

Besim Ben-Nissan, Doron Sher, William Walsh

Pages:

867-870

DOI:

10.4028/www.scientific.net/KEM.240-242.867

Citation:

R.M. Gillies and W.R. Walsh, "The Influence of Boundary Conditions on Finite Element Analysis", Key Engineering Materials, Vols. 240-242, pp. 867-870, 2003

Online since:

May 2003

Export:

Price:

$35.00

[1] JM Drouin and B Cales. Finite Element Analysis of Stress in Zirconia Femoral Heads. in 3rd Symposium of European Institute on Biomaterials and Microsurgery. 1992. Nancy, France.

[2] JL Gilbert, CA Buckley, and JJ Jacobs: In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling. J Biomed Mater Res. 27: 1533-44, (1993).

DOI: 10.1002/jbm.820271210

[3] SD Cook, RL Barrack, and AJ Clemow: Corrosion and wear at the modular interface of uncemented femoral stems. J Bone Joint Surg Br. 76: 68-72, (1994).

[4] PZ Wirganowicz and BJ Thomas: Massive osteolysis after ceramic on ceramic total hip arthroplasty. A case report [see comments]. Clin Orthop. 100-4, (1997).

DOI: 10.1097/00003086-199705000-00015

[5] B Cales and Y Stefani: Risks and advantages in standardization of bores and cones for heads in modular hip prostheses. J Biomed Mater Res. 43: 62-8, (1998).

DOI: 10.1002/(sici)1097-4636(199821)43:1<62::aid-jbm7>3.0.co;2-k

[6] J Charnley: Total hip replacement by low-friction arthroplasty. Clin Orthop. 72: 7-21, (1970).

[7] NH Shareef and DL Levine, Study of the behaviour of tapered contact surfaces in modular hip prosthesis joints using finite element method, L. DL, Editor. 1996, Zimmer, Inc.

[8] H Fessler and DC Fricker: Friction in femoral prosthesis and photoelastic model cone taper joints. Proc Inst Mech Eng [H]. 203: 1-14, (1989).

DOI: 10.1243/pime_proc_1989_203_003_01

[9] HG Pfaff: Ceramic component failure and the role of proof testing. Clin Orthop. 29-33., (2000).

[10] G Bergmann, F Graichen, and A Rohlmann: Hip joint loading during walking and running, measured in two patients. J Biomech. 26: 969-90, (1993).

DOI: 10.1016/0021-9290(93)90058-m

[11] KL Johnson, Contact Mechanics. 1985, Cambridge, Great Britian: Cambridge University Press.

[12] S Affatato, E Ghisolfi, GL Cacciari, et al.: Alumina femoral head fracture: an in vitro study. Int J Artif Organs. 23: 256-60., (2000).

In order to see related information, you need to Login.