Tension-Dependent Internal Damping of a Cable Model

Abstract:

Article Preview

Info:

Periodical:

Key Engineering Materials (Volumes 243-244)

Edited by:

Mamtimin Geni and Masanori Kikuchi

Pages:

415-420

Citation:

G. Zheng et al., "Tension-Dependent Internal Damping of a Cable Model", Key Engineering Materials, Vols. 243-244, pp. 415-420, 2003

Online since:

July 2003

Export:

Price:

$38.00

[1] T. Miyata. Design Consideration for Wind Effects on Long-Span Cable-Stayed Bridges., Cable-Stayed Bridges: Recent Developments and Their Future, Ito, M. et al. (Editors). Elsevier Science Publishers B. V., Tokyo, (1991), pp.235-256.

DOI: https://doi.org/10.1036/1097-8542.yb150602

[2] N. Narita and K. Yokoyama. A Summarized Account of Damping Capacity and Measures Against Wind Action in Cable-Stayed Bridges in Japan., Cable-Stayed Bridges: Recent Developments and Their Future, Ito, M. et al. (Editors). Elsevier Science Publishers B. V., Tokyo, (1991).

DOI: https://doi.org/10.1002/9783433601044.ch5

[3] C. Geurts, T. Vrouwenvelder, P. Staalduinen and J. Reusink. Numerical modelling of rain-wind-induced vibration: Erasmus Bridge, Rotterdam., Structural Engineering International. Vol. 2 (1998), pp.129-135.

DOI: https://doi.org/10.2749/101686698780489351

[4] M. Kazakevitch and A. Zakora Cable stabilization for wind and moving load effect, Journal of Wind Engineering and Industrial Aerodynamics. Vol. 74-76 (1998) pp.995-1003.

DOI: https://doi.org/10.1016/s0167-6105(98)00091-9

[5] T. Saito, M. Matsumoto and M. Kitazawa. Rain-wind excitation of cables on cale-stayed Higashi-Kobe Bridge and cable vibration control., Proceedings of IABSE/EIP International Conference: Cable-Stayed and Suspension Bridges, Deauvile, (1994).

[6] T. Miyata, H., Yamada, T. Hojo and S. Yamazaki. On aerodynamically stable PE-stay-cables with decreased drag force by introduction of newly developed lumped surface roughness., Proceedings of International Symposium: Cable Dynamics. Liege, Vol. 19-21 (1995).

[7] Y. Yamada, et al. Eqrthquake-resistant and wind-resistant design of the Higashii-Kobe Bridge., Ito M., Fujino, Y. Miyata, T. and Narita, N. (eds. ), Cable-Stayed Bridge - Recent Developments and Their Future. Elsevier. (1990), pp.397-416.

[8] T. Yoshmura, M.G. Savage and H. Tanaka Wind-induced vibrations of bridge stay-cables., Proceedings of International Symposium on Cable Dynamics. Liege, (1995), pp.437-444.

[9] G.D. Gounaris and N.K. Anifantis Structural damping determined by finite element approach, Computers and Structures. Vol. 73 (1999), pp.445-452.

DOI: https://doi.org/10.1016/s0045-7949(98)00257-0

[10] Y.Q. Ni, J.M. Ko and G. Zheng Free and forced vibraiton of large-diameter sagged cbles taking into account bending stiffness., Advances in Steel Structures: proceedings of the Second International Conference on Advances in Steel Structures. (S. L Chan and J.G. Teng eds. ), Vol. 1 (1999).

DOI: https://doi.org/10.1016/b978-008043015-7/50060-9

[11] G. Zheng Ambient vibration tests of six stay cables on the Dongting Lake cable-stayed bridge., Report No. DLB-02, Department of Civil and Structural Engineering, The Hong Kong Polytechnic University, May 2001, 37p.

[12] J.M. Ko, G. Zheng, Z.Q. Chen and Y.Q. Ni Field vibration tests of bridge stay cables incorported with magneto-rheological (MR) dampers., to appear in Smart Structures and Materials 2002: Smart Systems for Bridges, Structures, and Highways, S. C. Liu and D. J. Pines (eds. ), SPIE Vol. 4696, (2002).

DOI: https://doi.org/10.1117/12.472567

[13] R.W. Clough and J. Penzien Dynamics of Structures, McGrqw-Hill, Inc, Singapore (1993).