Consideration of Uncertainty in Diagnosis for Railway Arrester

Abstract:

Article Preview

This paper presents a method for diagnosis of railway arrester considering uncertainty. Arresters, a protective device that prevents damage due to transient voltages, deteriorate due to the absorption of moisture, repetitive operation during over-voltages and manufacturing defects. Various diagnostic techniques are available for monitoring deterioration of arresters. The technique based on the amplitude of leakage current measures the root mean square or peak values of leakage current components. After measuring the total leakage current, harmonics of leakage current components are analyzed by using a microprocessor based device. The level of leakage current is indicative of the arrester conditions. Harmonics of leakage current components occur due to nonlinear characteristics of railway arrester. Since leakage current contains uncertainty characteristics of power source, the probability density functions of leakage current components can be obtained for ZnO arrester. This paper presents a probabilistic approximation method for the harmonic currents analysis in diagnosis for railway arresters. Mean and variance of harmonic currents in railway system are obtained based on leakage current components. These statistical measures can be helpful to reduce the diagnostic error for railway arrester.

Info:

Periodical:

Key Engineering Materials (Volumes 321-323)

Edited by:

Seung-Seok Lee, Joon Hyun Lee, Ik Keun Park, Sung-Jin Song, Man Yong Choi

Pages:

1507-1512

DOI:

10.4028/www.scientific.net/KEM.321-323.1507

Citation:

H. C. Kim et al., "Consideration of Uncertainty in Diagnosis for Railway Arrester", Key Engineering Materials, Vols. 321-323, pp. 1507-1512, 2006

Online since:

October 2006

Export:

Price:

$35.00

[1] S. Shirakawa et al, Maintenance of surge arrester by portable arrester leakage current detector, IEEE Transaction on Power Delivery, Vol. 3, No3, pp.998-1003, (1988).

DOI: 10.1109/61.193879

[2] J. Lundquist et al, New method for measurement of the resistive leakage currents of metal-oxide surge arrester in service, IEEE Transaction on Power Delivery, Vol. 5, No. 4, pp.1811-1822, (1990).

DOI: 10.1109/61.103677

[3] S. Tominaga, Y. Shibuya, T. Fujiwara, M. Imataki, T. Nitta, Stability and Long Term Degradation of Metal Oxide Surge Arresters, IEEE Trans. on PAS., vol. PAS-99, no. 4, p.1548~1556, (1980).

DOI: 10.1109/tpas.1980.319580

[4] Gyung-Suk Kil, Joo-Sup Han, Characteristic Changes of ZnO Arrester Blocks by Multiple-lightning Impulse Currents, Trans. of the KIEE, vol. 49C, no. 12, p.685~690, (2000).

[5] Y. Yamashita, S. Yoshikado, Evaluation of factors in the degradation of ZnO varistor, T. IEE Japan, vol. 119-B, no. 6, p.652~657, (1999).

[6] Hanxin Zhr, M.R. Raghuveer, Influence of Harmonics in System Voltage on Metal Oxide Surge Arrester Diagnostics, Proceedings 1999 Conference on Electrical Insulation and Dielectric Phenomena, p.542~545, Austin, (1999).

DOI: 10.1109/ceidp.1999.807862

[7] H. Song, J. Kim, Hyungchul Kim, A Harmonics Analysis of AC High Speed Railroad(HSR) System using Probabilistic Approach, Korean Society for Railway, May, (2005).

[8] H. Song, J. Kim, Hyungchul Kim, A Harmonics Analysis of railway using Probabilistic Approach, KIEE Summer Conference, Pyongchang, July 19, pp.214-216 (2005).

[9] A. Papoulis, S. U. Pillai, Probability, Random variables, and Stochastic Process, 3 rd Ed., McGraw-Hill, New York, (1991).

In order to see related information, you need to Login.