In Vitro Biocompatibility of a New High Nitrogen Nickel Free Austenitic Stainless Steel

Abstract:

Article Preview

The in vitro blood compatibility of a new nickel free high nitrogen austenitic stainless steel Fe-Cr-Mn-Mo-N (BIOSSN4) was studied by the kinetic clotting time test and the platelet rich plasma adhesion test in this paper. In comparison with 316L stainless steel, the kinetic clotting time of BIOSSN4 steel are longer, and only causes less activation of platelets in platelet adhesion test, which was indicated by their morphology and low spreading. The experimental results reveals that the BIOSSN4 stainless steel has better blood compatibility, the blood compatibility mechanism of steels was analyzed based on surface tension and interfacial tension between the steels and blood.

Info:

Periodical:

Key Engineering Materials (Volumes 342-343)

Edited by:

Young-Ha Kim, Chong-Su Cho, Inn-Kyu Kang, Suk Young Kim and Oh Hyeong Kwon

Pages:

605-608

Citation:

Y. B. Ren et al., "In Vitro Biocompatibility of a New High Nitrogen Nickel Free Austenitic Stainless Steel", Key Engineering Materials, Vols. 342-343, pp. 605-608, 2007

Online since:

July 2007

Export:

Price:

$38.00

[1] J. Black, G. Hastings: Handbook of biomaterial properties (London: Chapman&Hall, 1998).

[2] Klein CL, Nieder P, Wagner M, et al: J Pathophysiol. Vol. 5 (1994), pp.798-807.

[3] J. Beddoes, K. Bucci: Journal of Materials Science: Materials in Medicine Vol. 10(1999), pp.389-394.

[4] E. Denkhaus A, K. Salnikow: Critical Reviews in Oncology/Hematology Vol. 42 (2002), pp.35-56.

DOI: https://doi.org/10.1016/s1040-8428(01)00214-1

[5] A Yamamoto, Y Kohyama, D Kuroda, T Hanawa: Materials Science and Enginerring: C Vol. 24 (2004), pp.737-743.

[6] M Fini, N Nicoli Aldini, P Torricelli, et al: Biomaterials Vol. 24(2003), p.4929~4939.

[7] Ren Yibin, Yang Ke, Zhang Bingchun, et al: Journal of Materials Science and Technology Vol. 20(2004), pp.571-573.

[8] ASTM F2229-02, Standard Specification for Wrought, Nitrogen Strengthened 23 Manganese-21 Chromium-1Molybdenum Low-nickel Stainless Steel Alloy Bar and Wire for Surgical Implants (UNS S29108).

DOI: https://doi.org/10.1520/f2229

[9] Yibin Ren, Ke Yang, Bingchun Zhang: Materials Letters Vol. 59 (2005), pp.1785-1789.

[10] S Agathopoulos, P Nikolopoulos: Journal of Biomedical Materials Research Vol. 29 (1995), pp.421-429.

[11] J Y Chen, Y X Leng, X B Tian, et al: Biomaterials Vol. 23 (2002), p.2545~2552.

[12] Engbers G H: Foreign Medicine, Biomedical Engingeering Section Vol. 15 (1992), pp.39-43.

[13] Z Cao, F Lu: Chemistry Vol. 7(1994), p.15~20.

[14] Liang Hong, Ou Yangdi, Hu Xuying, et al: Acta Chimica Sinica Vol. 56( 1998),pp.662-667.

[15] Shen Xincan, Bian Hedong, Tu Chuqiao, et a: Chinese journal of inorganic chemistry Vol. 16 (2000), pp.73-78, in Chinese.

[16] Wang Chunren, Yang Zibin, Xi TingFei: Biomedicine engineering foreign medical sciences Vol. 18 (1995), pp.334-339, in Chinese.